Herunterladen Inhalt Inhalt Diese Seite drucken

Exchanging The Carbon Filter - VHF N4+ Originalbetriebsanleitung

Dentalmaschine
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 69
EN 46
15. Go to the next step of the on-screen guide.
The cleaning process starts. The remaining time dis-
plays in the info area of DENTALCNC's main applic-
ation window.
16. Wait until the process is finished.
17. Open the cooling liquid drawer.
18. Empty the cooling liquid tank. Refill it with drinking
water without cooling lubricant.
19. Insert the tank into the machine.
20. Close the cooling liquid drawer.
21. Go to the next step of the on-screen guide.
The rinsing process starts. The remaining time dis-
plays in the info area of DENTALCNC's main applic-
ation window.
22. Wait until the process is finished.
23. Go to the next step of the on-screen guide.
24. Open the working chamber door.
25. Dry the working chamber with a cloth.
26. Open the cooling liquid drawer.
27. Empty the cooling liquid tank.
28. Exchange the carbon filter.
filter – see below
29. Thoroughly clean the cooling liquid tank.
30. Fill in cooling liquid for processing.
the cooling liquid and cleaning the tank – on page  29
31. Insert the tool magazine into the working chamber.
Exchanging the carbon
Exchanging
Original Operating Instructions:  N4+
Version: 12/16/2021
N4+ – Maintenance and do-it-yourself

8.10 Exchanging the carbon filter

F
. 66 C
IG
OOLING LIQUID FILTER IN THE TANK
F
. 67 T
IG
HE COMPONENTS OF THE COOLING LIQUID FILTER
1. Fine filter
2. Carbon filter cap
3. Carbon filter
4. Mesh filter
To exchange the activated carbon pellets and clean the
filter, do the following:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis