5.9 CAD/CAM integration

If you use exocad ChairsideCAD as your CAD applic-
ation, you can activate the CAD/CAM integration with
DENTALCAM & DENTALCNC  8.
If you use the CAD  / CAM integration, you will nest
objects completely in the CAD application. On export,
DENTALCAM will automatically calculate the job and
send it to DENTALCNC for machining.
Requires exocad ChairsideCAD 2.3 with corresponding
service release published by exocad.
When nesting objects in exocad ChairsideCAD, you
can only use the middle position of the block holder.

5.9.1 Activating the CAD/CAM integration

There are 2 ways to set up the CAD/CAM integration
with your N4+ and exocad ChairsideCAD:
exocad ChairsideCAD is installed on the CAM
n
computer. This is recommended as it will simplify
the configuration process.
If you want to use this configuration, only perform
the
basic
configuration.
exocad ChairsideCAD is installed on a separate
n
computer ("CAD computer") which is connected
to the CAM computer via network.
If you want to use this configuration, perform the

basic configuration

and the
uration.
5.9.2 Basic configuration
1. Open the DENTALCNC Application settings with the
following icon in the main icon  bar: 
2. Open the General settings with the following icon in
the local icon  bar: 
3. Activate the CAD/CAM integration activated option.
F
. 27 A
CAD/CAM
IG
CTIVATING THE
DENTALCNC
4. Open the Machine data view with the following icon
in the local icon  bar: 
exocad network config-
INTEGRATION IN
Original Operating Instructions:  N4+
Version: 12/16/2021
N4+ – Installing the machine
5. Activate the unlock option for exocad Chair-
sideCAD in DENTALCNC.
F
. 28 T
CAD/CAM
IG
HE
INTEGRATION OPTIONS IN THE
DATA VIEW
If you installed exocad ChairsideCAD onto the CAM
computer, you are finished.
6. If exocad ChairsideCAD is installed on a separate
CAD computer, continue with the
configuration.
5.9.3 exocad netw ork configuration
Only perform the following procedure if exocad Chair-
sideCAD is installed on a different computer than
DENTALCAM & DENTALCNC.

5.9.4 Configuring the CAM computer

1. Access the CAM computer.
2. Create the following folder:
C:\CADshare\DentalNestingObjToMDW
3. Share this folder in your network. The CAD
computer requires read and write access to it.
5.9.5 Checking the data transfer folder set-
ting
1. Open the DENTALCNC Application settings with the
following icon in the main icon  bar: 
2. Open the General settings with the following icon in
the local icon  bar: 
3. Check if the following folder path displays under
the CAD/CAM integration: Data transfer folder label:
C:\CADshare\DentalNestingObjToMDW