Interval
Where?
First after 200
operating
hours, then
every 2000
operating
hours
Every month
Maintenance
Version 2.1.2 - 2021-09-22
What?
How?
For oil change use an appropriate collecting tray of sufficient
capacity.
Unscrew the screw from the drain hole.
Img.6-4:
Changing the oil in the gear of the drilling spindle sleeve
Re-fill the gear with gear oil. Approx. consumption 4.5 litres.
Pay attention to the correct level.
Operating material on page 69.
Oil the drilling column in regular intervals using standard oil.
Lubricate the rack regularly with commercial grease (e.g.
friction bearing grease).
Translation of original instruction
B40 GSP
EN