Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Characteristics - tau K126MA Installationsanleitung

Vorschau ausblenden Andere Handbücher für K126MA:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 28
ATTENTION:
-
do not use single cables (with one single wire), ex. telephone cables, in order to avoid break-
downs of the line and false contacts;
-
do not re-use old pre-existing cables;
-
In case of long sections of cables (> 20 m) for N.O./N.C. controls (e.g. OPEN / CLOSE, STOP, PEDE-
STRIAN, etc.), in order to avoid gate malfunctions, it will be necessary to uncouple the various
controls using RELAYS or using our 750T-RELE device.
2. INTRODUCTION
The K126MA board has two working modes, selectable through the J6 jumper (see wiring diagram).
J6 Jumped:
J6 Not jumped:
Once the connection is achieved, in low-energy mode, press the PROG button briefly:
All the green LEDs must be on (each of them corresponds to a Normally Closed input). The go off
only when the controls to which they are associated are operated.
All the red LEDs must be off (each of them corresponds to a Normally Open input). The light up
only when the controls to which they are associated are operated.

3. TECHNICAL CHARACTERISTICS

Board power supply
Max. absorption DC motor
Fast acting fuse for protection of input power supply 13,5V AC (F4 - 5x20)
Fast acting fuse for battery charger protection (F5 - 5x20)
Fast acting fuse for protection of auxiliary circuits 18V
Motor power supply circuits voltage
Auxiliary device circuits supply voltage
Logic circuits supply voltages
Operating temperature
18V for MASTER-R and T-ONE8BR
1
24V for MASTER-R and T-ONE8BR
2
4. CONNECTIONS TO TERMINAL BOARD
Terminals Function
FS1 - FS2
POWER SUPPLY
1 - 2
AUX INPUT
3 - 6
PEDESTRIAN
standard mode, i.e. the control unit is powered all the time;
low consumption mode, at the end of each maneuver the board automatically switches
OFF itself and all the auxiliary devices connected. The board will automatically switch
ON again activating the OP/CL contact or pressing the remote (mode where power is
supplied by other energy sources, ex. batteries charged by a photovoltaic panel).
Description
13,5V (18V for
MASTER-R and T-ONE8BR) AC control unit power supply in-
put – Fed by
the toroidal transformer and protected by the fuses
on the 230V AC power supply.
external power input (ex. Photovoltaic system 12V DC).
NB: In the latest versions of the control boards, the voltage change
through jumper J7 is no longer necessary (make sure whether it is
present on the control board or not).
ATTENTION: POWERING THE CONTROL UNIT WITH AN EXTERNAL
SOURCE, ALL THE OTHER 18V (24V for MASTER-R) DC OUTPUTS BE-
COME THE SAME AS THE OUTSIDE VOLTAGE.
N.O. input for PEDESTRIAN button
of the complete journey) and it is subject to the setting of DIP SW 2 and 4.
(3= PED - 6= COM)
DC (F3 - 5x20)
2
- Controls prtial opening and closing (1/3
17
230 V AC - 50 Hz
14 Ah - 18V DC
10,5 Ah - 24 V DC
F 16A
F 10A
F 3.15A
18V
DC
2
18V
DC
2
5V DC
-20 °C ÷ +55 °C
(F 6,3A)

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis