Technical Characteristics - tau K123M Installationsanleitung

Steuerplatine fuer den getriebemotor master12q
Vorschau ausblenden Andere Handbücher für K123M:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 20
CONTROL BOARD FOR MASTER12Q GEARMOTOR
LOGICS WITH MICROPROCESSOR
STATUS OF INPUTS SIGNALLED BY LEDs
"PEDESTRIAN GATE" FUNCTION
INCORPORATED FLASHING CIRCUIT
ENCODER SENSOR FOR OBSTACLE DETECTION AND SELF-LEARNING OF TRAVEL
RECEIVER CONNECTOR
BATTERY CONNECTOR
BATTERY CHARGER BOARD (INTEGRATED)
DIAGNOSTICS OF MALFUNCTIONS SIGNALLED BY LED
TESTING
When you have completed the connection:
All the green LS LEDs must be on (each of them corresponds to a Normally Closed input).
The go off only when the controls to which they are associated are operated.
All the red LS LEDs must be off (each of them corresponds to a Normally Open input). The
light up only when the controls to which they are associated are operated.
ATTENTION:
-
do not use single cables (with one single wire), ex. telephone cables, in order to avoid
breakdowns of the line and false contacts;
-
do not re-use old pre-existing cables<
-
we recommend to use the TAU cable code M-03000010C0 to connect the motors to the
control board.

TECHNICAL CHARACTERISTICS

Board power supply
Max motor power DC
Fast acting fuse for protection of input power supply 13.5 Vac (F1 - 5x20)
Fast acting fuse for motor protection (F2 - 5x20)
Fast acting fuse for protection of auxiliary circuits 18 V dc (F3 - 5x20)
Fast acting fuse for protection of battery (F4 - 5x20)
Motor power supply circuits voltage
Auxiliary device circuits supply voltage
Logic circuits supply voltages
Operating temperature
CONNECTIONS TO TERMINAL BOARD
Terminals
Function
1 - 2
MOTOR 18V DC motor supply output 18V DC max. 50 W;
3 - 4
5 - 6
PHOTOCELL TX
7 - 8
FLASHING LIGHT
14
Description
auxiliary circuits output 18V DC max. 15 W (3 = NEGATIVE -
AUX
4 = POSITIVE) for photocells, relays, receivers, etc...;
18V DC output for transmitter photocell – phototest - (5 =
NEGATIVE - 6 = POSITIVE) max. no. 1 photocell transmitter;
18V DC max. 20W output for flashing light supply (7 = NEGA-
TIVE - 8 = POSITIVE), flashing signal supplied by the control
unit, rapid for closing, slow for opening;
K123M
13,5V AC - 50 Hz
50 W - 18V DC
F 15A
F 15A
F 1,6A
F 10A
18V DC
18V DC
5V DC
-20 °C ÷ +55 °C