TRWinProg Parameterization: CO_58 / C_H80 / C_H110

8 TRWinProg Parameterization: CO_58 / C_H80 / C_H110

8.1 Basic parameters

8.1.1 Count direction

Selection
Increasing
Decreasing

8.1.2 Scaling parameters

The scaling parameters can be used to change the physical resolution of the
measuring system. The measuring system supports the gearbox function for round
axes.
This means that the Measuring units per revolution and the quotient of Revolutions
numerator / Revolutions denominator can be a decimal number.
The position value output is calculated with a zero point correction, the count direction
set and the gearbox parameter entered.
 TR-Electronic GmbH 2005, All Rights Reserved
Page 94 of 107
Danger of personal injury and damage to property exists if the
measurement system is restarted after positioning in the de-energized
state by shifting of the zero point!
If the number of revolutions is not an exponent of 2 or is >4096, it can occur, if
more than 512 revolutions are made in the de-energized state, that the zero
point of the multi-turn measuring system is lost!
Ensure that the quotient of Revolutions Numerator / Revolutions
Denominator for a multi-turn measuring system is an exponent of 2 of the
0
1
2
12
group 2
, 2
, 2
...2
or
• Ensure that every positioning in the de-energized state for a multi-turn
measuring system is within 512 revolutions.
Description
Measuring system position increasing clockwise
(view onto the flange connection)
Measuring system position decreasing clockwise
(view onto the flange connection)
TR - ECE - BA - DGB - 0039 - 14
(1, 2, 4...4096).
Default
X
Printed in the Federal Republic of Germany
07/30/2020