Herunterladen Inhalt Inhalt Diese Seite drucken

Ssi; Format; Tree Format No - TR-Electronic C 58 Serie Benutzerhandbuch

Vorschau ausblenden Andere Handbücher für C 58 Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7.2 SSI

7.2.1 Format

7.2.1.1 Tree format no

Tree format no = default setting
A synchronous-serial data transmission with Tree format no is min. 8 bits, or max.
32 bits long. The data transmission begins with the most significant bit (MSB) and
contains the position bits (P).
Related to a certain number of clocks, the data can be shifted arbitrarily by the
parameter Number of data bits. The data can be transmitted right-justified or
left-justified, with leading "zeros" and without leading "zeros". Leading "zeros" are
produced if the parameter Number of data bits is programmed larger, as it would
be necessary from the total measuring length.
Example
Measuring system:
-
-
-
-
-
Output right-justified
Programmed number of data bits = 24
MSB
1
2
0
0
Output left-justified
Programmed number of data bits = 22
MSB
Printed in the Federal Republic of Germany
07/30/2020
1024 steps/revolution (10 bits)
4096 revolutions (12 bits)
--> Total measuring length = 22 bits
Code: Binary or Gray
Number of clocks: 24
3 – 24
21
0
P 2
– P 2
1 – 22
21
0
P 2
– P 2
TR - ECE - BA - DGB - 0039 - 14
LSB
LSB
23
24
0
0
 TR-Electronic GmbH 2005, All Rights Reserved
Page 91 of 107

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis