Herunterladen Inhalt Inhalt Diese Seite drucken

Preset Value; Preset Function; Origin Type - TR-Electronic C 58 Serie Benutzerhandbuch

Vorschau ausblenden Andere Handbücher für C 58 Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5.1.3 Preset value

The parameter defines the position value, on which the measuring system is adjusted
when the preset-adjustment-function is executed via the Preset-input.
programmed Origin Type ≤
lower limit
upper limit
default

5.1.4 Preset function

If the Preset inputs are not used, they should be disabled to suppress interference.
Selection
In use
Not in use

5.1.5 Origin Type

The parameter defines the measuring system origin (start of counting). A value
different of "0" causes a zero shift and it results a negative or positive offset. If a
negative origin was defined, in the section "SSI" the type of representation
(Complement or Sign + value) for the negative values must be specified.
lower limit
upper limit
default
Printed in the Federal Republic of Germany
07/30/2020
Preset value
Risk of injury and damage to property by an actual value jump when the
Preset adjustment function is performed!
• The preset adjustment function should only be performed when the
measuring system is at rest, otherwise the resulting actual value jump must
be permitted in the program and application!
Description
Preset adjustment function active
Preset adjustment function inactive
TR - ECE - BA - DGB - 0039 - 14
< programmed Total number of steps
–1 073 741 824
1 073 741 823
0
–1 073 741 824
1 073 741 824
0
 TR-Electronic GmbH 2005, All Rights Reserved
Default
user-specific
Page 75 of 107

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis