7 TRWinProg Parameterization: CE_58 – 15 bit resolution
7.1 Basic parameters
7.1.1 Count direction
Selection
Increasing
Decreasing
7.1.2 Scaling parameters
The scaling parameters can be used to change the physical resolution of the
measuring system.
The position value output is decoded according to the programmed output code and is
calculated with a zero point correction and the count direction set.
The measuring system does not support decimal numbers or numbers of revolutions
(gearbox function) deviating from exponents of 2.
7.1.2.1 Total number of steps
The parameter defines the total number of steps of the measuring system before the
measuring system restarts at zero.
lower limit
upper limit
default
The actual upper limit for the measurement length to be entered in steps is dependent
on the measuring system version and can be calculated with the formula below. As
the value "0" is already counted as a step, the end value = Total number of steps – 1.
To calculate, the parameters Number of steps per revolution and the Number of
revolutions can be read on the measuring system nameplate.
Printed in the Federal Republic of Germany
07/30/2020
Description
Measuring system position increasing clockwise
(view onto the flange connection)
Measuring system position decreasing clockwise
(view onto the flange connection)
2 steps
134 217 728 steps (27 bit)
16 777 216
Total number of steps = Number of steps per revolution * Number of revolutions
TR - ECE - BA - DGB - 0039 - 14
Default
X
TR-Electronic GmbH 2005, All Rights Reserved
Page 89 of 107