8.2 SSI

8.2.1 Format

8.2.1.1 No special format

No special format = default setting
A synchronous-serial data transmission with No special format is min. 8 bits, or
max. 36 bits long. The data transmission begins with the most significant bit (MSB)
and contains the position bits (P).
Related to a certain number of clocks, the data can be shifted arbitrarily by the
parameter Number of data bits. The data can be transmitted right-justified or
left-justified, with leading "zeros" and without leading "zeros". Leading "zeros" are
produced if the parameter Number of data bits is programmed larger, as it would
be necessary from the total measuring length.
Example
Measuring system:
-
-
-
-
-
Output right-justified
Programmed number of data bits = 24
MSB
1
2
0
0
Output left-justified
Programmed number of data bits = 22
MSB
Printed in the Federal Republic of Germany
07/30/2020
1024 steps/revolution (10 bits)
4096 revolutions (12 bits)
--> Total measuring length = 22 bits
Code: Binary or Gray
Number of clocks: 24
3 – 24
21
0
P 2
– P 2
1 – 22
21
0
P 2
– P 2
TR - ECE - BA - DGB - 0039 - 14
LSB
LSB
23
24
0
0
 TR-Electronic GmbH 2005, All Rights Reserved