Fig. 49 Power supply connection
Fig. 50 Additional PE cable
Fig. 51 Automatic Cutouts
Suprasetter 106 – Installation
Route the power supply cable through the strain
relief into the Suprasetter and connect it to the ter-
minal block (Fig. 49/1) as per Tabelle Power con-
nection variants (Seite 64).
Fit the PE cable to the plate (Fig. 49/2).
The cable cross section must be 2.5 mm² (16A CEE
connector) for Europe and AWG 12 (3.3 mm²) (32A
CEE connector) for the USA.
Secure the cable to the bracket with a cable tie.
Attach the power supply box with the 4 screws
again.
Fasten the additional PE cable (Fig. 50/1) with the
M5 screw and secure the cable with the clamp.
Set automatic cutout F5 (Fig. 51/1) to OFF if the
Suprasetter is to be operated without an auto-
matic loader. Otherwise the power cable con-
nected at one end would act like an EMC antenna
in the Suprasetter.