Alternative procedure for the case that the recorder terminal should not work:
Sensitive electronics - Suprasetter and PC must be switched off. Connect and dis-
connect cables only when the machine is deenergized.
Prerequisite: Suprasetter, PC and APL are switched off.
1.
Connect the Suprasetter and PC (Suprasetter PC or service laptop) with a serial cable.
2. Start the terminal program (recommended: TeraTermPro).
3. Configure the serial connection (38400 N 1).
4. Switch on the Suprasetter.
5. Start the PC and GUI.
6. After the Suprasetter starts, press the space bar three times to go to the main menu of the Ser-
vice interface.
After that, continue in the terminal program as described in the previous section.