Fig. 37 Swivel table coupling
Fig. 38 Access to the load table
Fig. 39 Pull out load table
Suprasetter 106 – Installation
Set swivel table to 0° (horizontally) to allow the
loading table to be pulled out. To do so, turn the
coupling (Fig. 37/1) by hand.
Unscrew both screws (Fig. 38/1) (size 4 wrench) of
the cable protection and remove the plate (Fig.
38/2).
Remove the locking screws (Fig. 39/1) on both
sides of the load table.
Press together the springs (Fig. 39/2) and pull out
the table.