F1
12A
F2
12A
F3
6A
F4
6A
F5
6A
F6
12A
Tab. Assignment of automatic cutouts
Note: The power phases are assigned depending on the power selection X10 (see tables in
"Power connection variants", page
Danger! High Voltage!
You may suffer an electric shock if the power is adapted incorrectly.
Because power supply networks are different worldwide, power is adapted to the
local network by attaching the correct power encoding connector at two points:
on the Suprasetter and on the chiller.

Mechanical Hazards

Beware of moving parts in the Suprasetter
When the covering is open and the safety loop is bridged by the key-operated
switch, there is a risk of getting crushed in the area near the tilting table, in the
path traveled by the laser carriage and by the rotating cylinder.
Switch off Suprasetter during work in these areas.
Suprasetter 106 – Installation
Chiller
Main drive
Extractor fan
Laser power supply module
Automatic loader
Electronics box power sup-
ply module
64).