16 Technical data

• For dimensions, see sales catalog TS 2plus
• Maximum load/section load: 30 kg / 1.0 kg/cm support surface length
• Noise emissions: < 70 dB (A)

16.1 Ambient conditions

• The transfer systems have been designed for stationary use in a location that is
protected from the elements.
• Operating temperature
• Storage temperature
• Relative humidity
• Air pressure
• Max. load capacity of fl oor: 1000 kg/m
• At altitudes > 1400 m, the load values of the electric drives are reduced by 15 %.
• The area should be kept free of mold, fungus, rodents and other vermin.
• Do not install or operate in the immediate vicinity of industrial equipment
producing chemical emissions.
• Do not install or operate near sources of sand or dust.
• Do not install or operate in areas that are regularly subjected to high-energy forces
caused, for example, by presses or heavy machinery.
• Resistant to many media that are commonly found in manufacturing, such as water,
mineral oil, grease, and detergents. Contact your Rexroth representative if you have
any doubts about resistance to specifi c chemicals, such as test oil, doped oils,
corrosive detergents, solvents or brake fl uid.
• Avoid prolonged contact with highly reactive acidic or alkaline materials.

16.2 Pneumatics

• Oiled or non-oiled, fi ltered, dry compressed air.
• Operating pressure:
• Solids
– Particle size
– Particle quantity
• Humidity – water content
1
– Pressure dew point
)
1
) The pressure dew point should be at least 15 °C below the ambient temperature.
• Oil content:
– Oil quantity
+5 °C to +40 °C
–5 °C to +60 °C at 20 % reduced load
–25 °C to +70 °C
5 % to 85 %, non-condensing
> 84 kPa, corresponds to an altitude < 1400 m above
sea level
2
4 to 6 bar
≤ 5 µm
(Class 6 as per ISO 8573-1:2010)
3
≤ 5 mg/m
(Class 6 as per ISO 8573-1:2010)
≤ +3 °C
(Class 4 as per ISO 8573-1:2010)
3
≤ 1 mg/m
(Class 3 as per ISO 8573-1:2010)
3 842 358 735/2019-10, MIT: HD 2, Bosch Rexroth AG
Technical data
37/38