Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance And Repair; Cleaning And Care; Inspection - Bosch Rexroth HD 2 Montageanleitung

Hub-dreheinheit
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

10 Maintenance and repair

High electrical voltage!
Risk of severe injury or death from electric shock.
Disconnect the relevant system component before performing any maintenance
or repair work.
Secure the system against being switched back on unintentionally.
High pneumatic pressure!
Risk of severe injury or death.
Switch off the compressed air supply to the relevant system component before
performing any maintenance or repair work.
Secure the system against being switched back on unintentionally.
Hot electric motor surfaces during operation!
Risk of burns from touching hot surfaces above 65 °C.
Install appropriate guards.
Let the unit cool down for at least 30 minutes before performing
maintenance and/or repair work.
• Only inspect and adjust continuous conveyors that are in motion or operation when
the safety guards are in place.
• Observe DIN EN ISO 13857 when you remove or replace safety guards and/or
bypass safety equipment.
• Test runs with open paneling should only be performed by a person with
appropriate knowledge and experience using tip switches, and if there is no
possibility of interference from other switching devices.

10.1 Cleaning and care

Failure of bearings
Applying grease-dissolving substances to the bearing points, e.g. during cleaning,
leads to bearing failure. There is a risk of damage to property, and the service life
may be reduced.
Keep degreasers or aggressive cleaning agents away from the bearings!
Only clean the product with a damp cloth.
Failure of the toothed belt
Applying grease-dissolving substances to the toothed belt, e.g. when cleaning, leads
to the failure of the toothed belt. There is a risk of damage to property.
Keep degreasers or corrosive cleaning agents away from the toothed belt!
Only clean the product with a damp cloth.

10.2 Inspection

Lift rotate unit
Check the pneumatic connections regularly for leaks.
Maintenance and repair
WARNING
CAUTION
NOTICE
3 842 358 735/2019-10, MIT: HD 2, Bosch Rexroth AG