1.2 Combination possibilities

This prosthetic component is compatible with Ottobock's system of
modular connectors. Functionality with components of other manufac­
turers that have compatible modular connectors has not been tested.
Allowable ankle blocks and screw connections
Foot size [cm]
Reference number (ankle block and screw
24 to 30
Allowable foot adapters
Body weight
Foot size
[kg]
[cm]
≤100
22 to 30
101 to 125
26 to 27
28 to 30

2 Intended use

2.1 Indications for use
The product is intended exclusively for lower limb exoprosthetic fit­
tings.
2.2 Area of application
Our components perform optimally when paired with appropriate
components based upon weight and mobility grades identifiable by
our MOBIS classification information and which have appropriate
modular connectors.
The product is recommended for mobility grade 1 (indoor
walker) and mobility grade 2 (restricted outdoor walker).
kg
The maximum approved body weight is specified in the technical
data (see Page 15).
10
connection)
2K34=30 and 2Z22=M10
Reference number (foot
adapter)
2R8=M10, 2R31=M10,
2R54=M10
2R8=M10, 2R31=M10
2R31=M10

2.3 Environmental conditions

Storage and transport
Temperature range –20 °C to +60 °C (–4 °F to +140 °F), relative
humidity 20 % to 90 %, no mechanical vibrations or impacts
Allowable environmental conditions
Temperature range: –10 °C to +45 °C
Chemicals/liquids: fresh water, soapsuds, chlorine water
Moisture: Submersion: max. 1 h in 2 m depth, relative humidity: no
restrictions
Solids: Dust, occasional contact with sand
Clean the product after contact with humidity/chemic­
als/solids, in order to avoid increased wear and damage (see
Page 14).
Prohibited environmental conditions
Solids: highly hygroscopic particles (e.g. talcum), dust in high con­
centrations (e.g. construction site), intensive contact with sand
Chemicals/liquids: salt water, perspiration, urine, acids, continu­
ous use in liquid media

2.4 Service life

This product has been tested by the manufacturer with 2 million load
cycles according to ISO 22675. Depending on the patient's activity
level, this corresponds to a service life of 2 to 3 years.
3 Safety

3.1 Explanation of warning symbols

Warning regarding possible risks of accident or
CAUTION
injury.
Warning regarding possible technical damage.
NOTICE

Werbung