1.1 Construction and Function

The 1C51 Taleo Vertical Shock and 1C52 Taleo Harmony prosthetic feet are suitable for walking
on various surfaces and at a wide range of speeds. The heel strike is absorbed by the large,
replaceable heel wedge.
Carbon and polymer spring elements permit perceptible plantar flexion at heel strike, a natural
rollover movement and high energy return.
The prosthetic feet have a functional ring. The functional ring absorbs vertical impact loads and
permits slight torsional movements.
The Taleo Harmony is additionally equipped with a mechanical vacuum pump.
While walking, the vacuum pump is compressed and released again, thus generating the vacu­
um. The elevated vacuum in the prosthetic socket improves the connection between the user and
the prosthesis.

1.2 Combination possibilities

This prosthetic component is compatible with Ottobock's system of modular connectors. Func­
tionality with components of other manufacturers that have compatible modular connectors has
not been tested.

2 Intended use

2.1 Indications for use
The product is to be used solely for lower limb exoprosthetic fittings.
2.2 Area of application
Our components perform optimally when paired with appropriate components based upon weight
and mobility grades identifiable by our MOBIS classification information and which have appro­
priate modular connectors.
The product is recommended for mobility grade 3 (unrestricted outdoor walker)
and mobility grade 4 (unrestricted outdoor walker with particularly high demands).
kg
The table that follows shows the suitable spring stiffness of the prosthetic foot, matching the
patient's body weight and activity.
Body weight [kg]
Spring stiffness relative to body weight and activity level
up to 51
52 to 58
59 to 67
68 to 77
78 to 88
89 to 100
101 to 115
116 to 130
Normal activity level
1
2
3
4
5
6
7
8
High activity level
2
3
4
5
6
7
8
9