ELECTRICAL INSTALLATION
6.5.4

Connecting kit PS

6.6

Connecting the evaluation unit to the vehicle's electrical system

8 8
3 D S T R E A M I N G C A M E R A A N D D R I V E R A S S I S T A N C E S Y S T E M F O R A U T O M A T I O N
A N D C O L L I S I O N W A R N I N G | V I S I O N A R Y - B
1.
Connect the transmission cable to the sensor head and the evaluation unit.
2.
Connect the Ethernet cable to the evaluation unit and the computer.
3.
Connect the evaluation unit to the power cable.
NOTE!
Before commencing the electrical installation, check where the connections are to be
located. You must refer to the operating instructions issued by the vehicle manufacturer
at this stage.
PIN
Flex color
1
White
2
Brown
3
Gray
4
Green
5
Yellow
6
Pink
1.
Connect the voltage supply to the vehicle's electrical system as shown in the above
table (fuse box). Observe the connection diagrams in
2.
Use heat-shrinkable sleeves to insulate any exposed joints.
NOTE!
Protect the evaluation unit against electrical overloading. To do this, you can use the
supplied fuses.
Please note that failure to observe this measure will invalidate any warranty claims.
Description
GND
+Battery
+Ignition
+Discrete signal input (reverse gear)
+Discrete signal input (optional recorder activation)
+Discrete signal input, reserved
Section
3.
8022960/186T / 2020-08-27| SICK AG