Herunterladen Inhalt Inhalt Diese Seite drucken

Configuration And Operation; Detection Zone; Zone Limits - SICK Visionary-B Betriebsanleitung

3d-streaming-kamera und fahrerassistenzsystem zur automatisierung und kollisionsvermeidung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

CONFIGURATION AND OPERATION

8
Configuration and operation
8.1

Detection zone

8.1.1

Zone limits

9 0
3 D S T R E A M I N G C A M E R A A N D D R I V E R A S S I S T A N C E S Y S T E M F O R A U T O M A T I O N
A N D C O L L I S I O N W A R N I N G | V I S I O N A R Y - B
The Visionary-B allows up to two independent zones to be configured at the same time.
Depending on requirements, these can be connected to one another or located arbi-
trarily. The dimensions of the zones are freely configurable subject to the zone limits.
NOTE!
"Full performance zone" means the performance within this zone has been fully vali-
dated not only under laboratory conditions but also under real-life field conditions.
Full performance zone
Object class 1
Object class 2
Direc-
Min.
Max.
Min.
tion
value
value
value
Y
0.3 m
6.0 m
1.5 m
(Length)
X
-2.0 m
2.0 m
-2.0 m
(Width)
Full performance zone for object class 1
Full performance zone for object classes 3, 4 and 5
Object class 3
Object class 4
Max.
Min.
Max.
Min.
value
value
value
Value
5.0 m
0.5 m
5.0 m
0.5 m
2.0 m
2.0 m
-2.0 m
2.0 m
Full performance zone for object class 2
Object class 5
Max.
Min.
Max.
value
value
value
5.0 m
0.5 m
5.0 m
-2.0 m
2.0 m
-2.0 m
8022960/186T / 2020-08-27| SICK AG
Subject to change without notice

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Visionary-b cvVisionary-b ps

Inhaltsverzeichnis