34 | FSA 500 | Technical data
8.9.5
Oscilloscope measurement functions
Measurement
Measuring
functions
range
1)
Secondary voltage
5 kV – 50 kV
Primary voltage
20 V – 500 V
Voltage
200 mV – 200 V
5 V – 500 V
AC coupling
200 mV – 5 V
Current
2 A
5 A
10 A
20 A
30 A
Current
50 A
100 A
200 A
1000 A
The measuring range is positive or negative depending on
1)
the base line.
The measuring range is greater than the permissible measurement
2)
voltage
|
1 689 989 115
2013-08-30
Sensors
Secondary
2)
sensor
Primary connecting ca-
2)
ble (UNI 2)
Multi measuring cable
2)
CH1 / CH2
Measurement lead with
2)
voltage divider
Connecting cable
B+/B–
Current probe 30 A
Current probe 1000 A
8.9.6

Oscilloscope functions and specifications

Function
Input coupling
CH1/CH2
Input impedance
CH1/CH2 (to ground)
Input impedance
CH1/CH2 (electrically isolated)
Bandwidth
CH1/CH2 (to ground)
Bandwidth
CH1/CH2 (electrically isolated)
Bandwidth Measurement lead with
voltage divider
Bandwidth
1000 A current probe
Bandwidth
30 A current probe
Bandwidth
Secondary sensor
Bandwidth
Primary connecting cable (UNI 2)
Time ranges
(referenced to 500 sampling
points)
Time ranges
(referenced to 1 sampling point)
Time base accuracy
Vertical accuracy
Device without sensors
R Offset error for ranges > 1 V
R Offset error for ranges
200 mV – 1 V
Vertical resolution
Memory depth
Sampling rate per channel
(to ground)
Sampling rate per channel
8.10

Electromagnetic compatibility (EMC)

The FSA 500 satisfies the requirements of the EMC di-
rective 2004/108/EG.
i
The FSA 500 is a class/category A product as de-
fined by EN 55 022. The FSA 500 may cause high-fre-
quency household interference (radio interference)
so that interference suppression may be necessary.
In such cases the user may be required to take the
appropriate action.
Specification
AC/DC
1 MOhm
1 MOhm (5 – 200 V)
10 MOhm (200 mV – 2V)
> 1 MHz = 200 mV – 2 V
> 5 MHz = 5 V – 200 V
> 100 kHz = 200 mV – 2 V
> 500 kHz = 5 V – 200 V
> 500 kHz
> 1 kHz
> 50 kHz
> 1 MHz
> 100 kHz (20 V)
> 1 MHz (50 V – 500 V)
10 µs – 100 s
20 ns – 200 ms
0,01 %
± 2 % of measured value
± 0,3 % of measuring range
± 5 mV
10 bit
4 Mega sampling values
or 50 curves
40 Ms/s
1 Ms/s
Robert Bosch GmbH