5.
Operation
5.1
Switch-on / switch-off
5.1.1
Switch-on
!
To avoid the formation of condensation, allow the
FSA 500 to adjust to ambient temperature before
switching on the FSA 500.
Briefly press the ON/OFF switch (refer to Fig. 1,
Pos. 4).
 LED A flashes (green) after 4 seconds.
"
FSA 500 is ready for operation.
5.1.2
Switch-off
Manual switch-off
Press the ON/OFF switch for approx. 3 seconds.
 LED A off.
"
FSA 500 switched off.
Automatic switch-off in battery mode
An acoustic warning signal sounds if the FSA 500
has not been operated for 10 minutes in battery
mode. The FSA 500 is then switched off automati-
cally after 30 seconds. After turning the FSA 500
back on, the desired test step can be recalled in the
FSA 500 CompacSoft [plus] software.
5.2
Notes on measurement
DANGER – Risk of electric shock if measure-
ments are taken on motor vehicles without
connecting cable B–!
Measurements taken with connecting cable
B– not connected to vehicle ground or the
negative post of the battery will result in in-
jury, heart failure or fatal electric shocks.
For all measurements, connect the
FSA 500 by way of connecting cable B – to
vehicle ground or the negative post of the
battery.
DANGER – Risk of electric shock from ex-
cessively high measurement voltage.
The measurement of voltages in excess of
60 VDC/30 VAC/42 VACpeak using Multi
measurement leads CH1 / CH2 will result in
injury, heart failure or fatal electric shocks.
Never use Multi measurement leads CH1 /
CH2 to measure mains or similar voltages.
Robert Bosch GmbH
Operation | FSA 500 | 29
!
Measurements with FSA 500 are only permitted in a
dry environment.
!
The FSA 500 is not to be used for checking isola-
tion from the supply on electric and hybrid vehicles.
Measurements on high voltage capacitator ignitions
are not permitted, as voltage values above 300 Volt
are present for this ignition type.
!
Measurements on the CRI Piezo are only permitted
with special adapter cables (optional accessories).
!
The measuring probes included in the test prod set
(1 684 485 362) can only be used for measurements
below 30 volt.
General procedure for measurements on the vehicle:
1. Switch off the ignition.
2. Connect the FSA 500 with battery (B–) or motor
mass via connecting cable B–.
3. Connect required measuring lines to the vehicle.
!
Do not hold the measuring lines with your hand dur-
ing measurement.
4. Switch on ignition.
5. Perform measurement.
6. Switch off the ignition after measuring.
7. Disconnect measuring lines on the vehicle.
8. Disconnect connecting cable B–.
"
Measurement complete.
i
Measurement deviations may occur during battery
charging.
i
Battery operation is not possible during 24 h meas-
urements (battery life < 4 h). The FSA 500 must then
be provided with power from the power supply unit.
The DCU 130 or PC/laptop must also stay enabled
during that time (e.g. sleep mode in Windows oper-
ating system should not be set).
5.3
Software update
i
Proceed as described in Section 4.3 to update the
software.
en
|
1 689 989 115
2013-08-30