Herunterladen Inhalt Inhalt Diese Seite drucken

Led Displays; Remote Trigger - Bosch FSA 500 Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für FSA 500:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
3.5.3
FSA 500 connection panel
DANGER – Risk of electric shock from
excessively high measurement voltage.
The measurement of voltages in excess of
60 VDC/30 VAC/42 VACpeak using Multi
measurement leads CH1 / CH2 will result in
injury, heart failure or fatal electric shocks.
Never use Multi measurement leads CH1 /
CH2 to measure mains or similar voltages.
459903-02_Ko
1
2
3
4
5
Fig. 2:
FSA 500 connection panel (viewed from underneath)
Item
Color code
Connection
1
Red/black
Connecting cable B+/B–
(connecting cable B– for vehicle
ground)
2
Green or
Secondary measuring transduc-
white or yel-
er or current probe 30 A or cur-
low
rent probe 1000 A or adapter cable
1 681 032 098 with fluid pressure
sensor (both special accessories)
3
Green or red
Multi measurement lead CH2 or
or yellow
measurement lead with voltage di-
vider or current probe 30 A or cur-
rent probe 1000 A
4
Green or blue
Multi measurement lead CH1 or
or yellow
measurement lead with voltage di-
vider or current probe 30 A or cur-
rent probe 1000 A
5
-
Coupling with hose (atmospheric
pressure measurement)
6
-

Remote trigger

7
White/black
Clip-on trigger or adapter cable
1 684 465 513 for clip-on sensor
8
Blue/white
Oil temperature sensor, air and IR
temperature sensor (special acces-
sories)
9
Yellow/green
Primary connecting cable (UNI 2)
10
-
Power supply unit connection
11
-
-
Connection for charging station
(special accessory)
For speed measurements with a clip-on sensor, the adapter
1)
cable 1 684 465 513 must always be connected between the
FSA 500 socket (Pos. 7) and the connecting cables for the
clip-on sensor.
The color codings on the connection cables refer to the correct
2)
connection at the FSA 500.
Robert Bosch GmbH
6
9
7
8
10
11
2)
1)
Product description | FSA 500 | 25
3.5.4

LED displays

LED A: Status indicator
Status
LED A
Not lit
FSA 500 off.
Red light
FSA 500 starting.
Flashing
FSA 500 on, but not yet ready for operation.
white
No data link with PC/Laptop.
(1 Hz)
Flashing
FSA 500 ready for operation.
green
Data link to PC/Laptop established via USB.
(1 Hz)
Flashing
FSA 500 ready for operation.
blue (1 Hz)
Data link to PC/Laptop established via Bluetooth.
Flashing
Firmware error.
red (4 Hz)
FSA 500 not ready for use.
LED B: Charge indicator
Status
LED B
Not lit
No external power
supply connected.
Power supply via battery.
Violet light
External power supply
connected. Battery being
charged.
Blue light
External power supply
connected. Battery is
charged.
Red light
External power supply
connected.
Possible cause of
trouble:
R Battery temperature
> 45 °C
R Battery not connected
R Battery defective
R Connector defective
3.5.5
Remote trigger
The start soft key (F3) or the stop soft key (F4) in the
FSA 500 CompacSoft [plus] software can be activated
with the button on the remote trigger.
3
BOSCH
30V
1 684 463 828
Fig. 3:
Remote trigger (1 684 463 828)
1 Button
2 Strain relief
3 Connector for FSA 500
i
For connection refer to Fig. 2, Pos. 6.
en
Action
-
-
External power supply
can be disconnected.
Check battery and
connector.
Allow the FSA 500 to
cool down.
2
459903-041_Ko
|
1 689 989 115
2013-08-30
1