Herunterladen Inhalt Inhalt Diese Seite drucken

Measurement Functions; Engine Test - Bosch FSA 500 Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für FSA 500:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
en
32 | FSA 500 | Technical data
8.9

Measurement functions

8.9.1

Engine test

Measurement functions
Speed
Oil temperature
U-Battery
U-Term. 15
U-Term. 1
Ignition voltage,
spark voltage
Spark duration
Relative compression over starter current 0 – 200 Ass
U-Alternator ripple
I-Starter
I-Alternator
I-Glow plugs
I-Primary
Dwell angle
Dwell period
Pressure (atmospheric)
Duty cycle
Injection time
Pre-heating time
8.9.2
Multimeter
Measurement functions
Speed
U-Battery
U-Term. 15
U-DC
min./max.
I-1000 A
I-30 A
Resistance
(R-Multi 1)
Pressure P-Air
Pressure P-Fluid
Oil temperature
Air temperature
Diode test
R Test voltage
R Test current
Continuity test
The measuring range is greater than the permissible measurement voltage
1)
|
1 689 989 115
2013-08-30
Measuring ranges
Resolution
450 min
– 6000 min
10 min
-1
-1
100 min
– 12000 min
10 min
-1
-1
250 min
– 7200 min
10 min
-1
-1
100 min
– 500 min
10 min
-1
-1
-20 °C – 150 °C
0,1 °C
0 – 60 V DC
0.1 V
0 – 60 V DC
0.1 V
0 –10 V
10 mV
0 – 20 V
20 mV
±50 kV
1 kV
±10 kV
0,1 kV
0 – 10 ms
0,01 ms
0,1 A
0 – 200 %
0.1 %
0 – 1000 A
0.1 A
0 – 30 A
0.1 A
0 – 100 %
0,1 %
0 – 360 °
0,1 °
0 – 50 ms
0,01 ms
50 ms – 100 ms
0,1 ms
-800 hPa – 1500 hPa
1 mbar
0 – 100 %
0.1 %
0 – 25 ms
0.01 ms
0 – 20 ms
0.01 ms
Measuring ranges
Resolution
As for engine test
0 – 60 V DC
72 mV
0 – 60 V DC
72 mV
1)
±200 mV – ±20 V
0.001 V
0.01 V
±20 V – ±200 V
1)
±1000 A
0.1 A
±30 A
0.01 A
0 – 1000 Ω
0.001 Ω
1 kΩ – 10 kΩ
0.1 Ω
10 kΩ – 999 kΩ
100 Ω
-800 hPa – 1500 hPa
2,5 hPa
0 – 1000 kPa
0,25 kPa
-20 °C – 150 °C
0,2 °C
-20 °C – 100 °C
0,1 °C
max. 4,5 V
max. 2 mA
0 – 10 Ohm
Sensors
Connecting cable B+/B–
-1
Clip-on trigger, secondary sensor,
-1
Primary connecting cable (UNI 2)
Current probe 30 A, diesel clip-on sensor,
-1
current probe 1000 A (starter current)
-1
Oil temperature sensor
Connecting cable B+/B–
Primary connecting cable (UNI 2)
Primary connecting cable (UNI 2)
Primary connecting cable (UNI 2),
secondary sensor
Primary connecting cable (UNI 2),
secondary sensor
Primary connecting cable (UNI 2),
secondary sensor
Multi measurement lead CH1
Current probe 1000 A
Current probe 30 A
Primary connecting cable (UNI 2)
Secondary sensor
Current probe 30 A
Atmospheric pressure sensor
Multi measurement lead CH1 / CH2
Multi measurement lead CH1 / CH2
Multi measurement lead CH1 / CH2
Sensors
Connecting cable B+/B–
Primary connecting cable (UNI 2)
Multi measurement lead CH1 / CH2
Current probe 1000 A
Current probe 30 A
Multi measurement lead CH1
Atmospheric pressure sensor
Oil temperature sensor
Air temperature sensor
Robert Bosch GmbH