1. Operating instructions

Description

The DHB hydraulically-controlled
instantaneous water heater heats the water
when the required volume of water flows
through the device.
Important information - in
brief
A
Power selector switch
! To change the heating output to the
required level.
B
Shower comfort switch
! For even more comfort when
showering.

Operation

A
Power selector switch
!!! Full output
! Automatic output modulation in 2 stages,
depending on the water volume, greatest
temperature increase,
/
or full load.
1
2
!! Energy saving
! Automatic output modulation in 2 stages,
energy saving with
/
or
/
heating load
1
2
3
3
(summer operation).
! Half load
! Fine adjustment to max.
/
heating load,
1
2
full heating capacity blocked (constant low
water requirement).
B
Shower comfort switch
Variable setting
1
! Fine adjustment of water volume and
2
temperature when showering, with hot
3
water tap fully opened.
1
4
Latching position
2
5
! For high temperatures, or with low
3
6
pressure in the hot water system.
4
7
5
Trouble-shooting in the
8
6
event of problems
9
7
# Set the output selector switch to the
10
8
basic setting !!!.
11
9
1
# Set the shower comfort switch to the
12
basic position
.
10
2
13
# Check fuses.
11
3
14
# Check the fittings and shower head for
12
4
15
lime scale or dirt.
13
5
See page 15 for more fault-finding
16
14
6
information.
17
15
7
18

Recommended settings

16
8
19
# for supplying bathroom and
17
9
20
kitchen:
18
10
21
A
Power selector switch
:
19
11
22
! Position !!!
20
12
23
B
1
Shower comfort switch
:
21
13
24
! Latching position
.
2
22
14
! The desired temperature is adjusted at
3
23
15
the fitting.
4
24
16
5
17
6
18
7
19
for the user and the qualified installer
# For suppling bathroom only:
A
Power selector switch
:
! Filling bath, position !!!.
! Showering in summer, position !!.
B
Shower comfort switch
:
! Hot water valve fully open.
! With sufficient pressure in the water
system, adjust the shower temperature
with the shower comfort switch.
#
Operation with two-handle fitting/
mono-bloc mixer
The DHB automatically controls the
individual heat output depending on the
water flow rate (Stages $ and $$) through the
device. To do this, a minimum volume is
required for actuation (see "Technical
Data").
Sink:
! Open the hot water tap of the two-
handle fitting or set the mono-bloc mixer
to the Hot setting. With a low flow
volume, the device will switch on heating
stage $. By reducing the flow at the hot
water tap, the output temperature can
be increased, and reduced by opening
the tap further.
Shower/bath/basin:
! With the hot water tap fully open/mono-
bloc mixer at the hot setting, the device
will operate automatically in Stage $$. The
output temperature and hot water
volume can be changed by means of the
B
shower comfort switch
in cold water at the fitting.
# Operation with thermostatic fitting:
A
Power selector switch
:
! Position !!! or !!
Take note of the instructions provided by the
manufacturer of the fitting.
! The desired temperature at other tap
points is adjusted at the fitting.
B
Shower comfort switch
:
! Always in the latching position
# With low pressure in the water system,
1
the shower comfort switch is to be set to
the latching position
.
2
The pressure loss in the downstream
3
fitting and in the hand-held shower in
4
particular, influences the temperature
5
selection possibility at the shower comfort
6
switch. Use hand-held showers with low
pressure loss (see page 14 for Relexa
7
hand-held shower).
8
9
Energy saving tip
10
The position !! saves energy and
11
water when showering, especially
12
in Summer. For filling the bath, the
13
power stage !!! is
recommended (shorter filling time).
14
15
16
17

Important information

When selecting the temperature at
the draw-off fitting, water
temperatures of over 60 °C may be
reached. For this reason, children should
be kept away from the fitting, due to the
risk of scalding.
Air in the cold water pipe will destroy the
bare-wire heating system of the DHB. If
the water supply to the DHB has been
interrupted, for example due to the risk of
frost or work on the water pipe, the
following steps must be carried out before
the system is used again:
1. Disconnect the supply or disconnect the
fuses.
2. Open a hot water tap downstream of
the device for as long as is necessary for
the device and the cold water pipe to be
freed of air.
3. Reconnect the supply or connect the
fuses again.
Hot water output
Depending on the time of year, a variety of
cold water supply temperatures can be
obtained which in turn give the following
maximum flow volumes or mixed water
volumes (see table 1).
%
= Cold water inlet temperature
1
%
= Mixing water temperature.
2
%
= Outlet temperature.
3
Useful temperatures:
– Approx. 38 °C: E.g. for shower, hand was-
hing, bath filling, etc.
– Approx. 60 °C: For kitchen washing and
when using thermostat fittings (shower
comfort switch in latching position
or by mixing
%
= 38 °C (Mixing water temperature)
2
kW
11,1
%
l/min
1
6 °C
4,9
10 °C
5,7
14 °C
6,6
%
= 60 °C (Outlet temperature)
3
kW
11,1
%
l/min
1
1
6 °C
2,9
2
10 °C
3,1
3
14 °C
3,5
4
Table 1
5
Maintenance
6
Maintenance work may only be
7
carried out by a qualified installer.
8
An overview of faults which you can rectify
9
yourself is provided on page 15.
10
Care
11
A damp cloth is all that is needed to care for
12
the housing. Do not use any abrasive or
aggressive cleaning agents.
13
14
Instructions for use and installation
15
Keep these instructions in a safe
16
place, and give them to the new
17
owner if you move house; if maintenance
or repair work is required, let the qualified
18
installer have them for reference.
19
20
21
1
).
2
3
4
18
21
24
27
5
6
8,0
9,4
10,7
12,1
9,2
10,7
12,3
13,8
7
10,7
12,5
14,3
16,1
8
9
18
21
24
27
10
11
4,8
5,6
6,4
7,2
12
5,2
6,0
6,9
7,7
13
5,6
6,5
7,5
8,4
14
15
16
17
18
19
20
21
22
23
24
11

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Dhb 18 siDhb 21 siDhb 27 siDhb 24 si

Inhaltsverzeichnis