OPERATION

Cleaning, care and maintenance

4.2

Recommended settings

Your instantaneous water heater offers maximum precision and
maximum convenience in DHW provision. Should you nonetheless
be operating the appliance with a thermostatic valve, we recom-
mend that you:
f Adjust the set temperature on the appliance to over 50 °C.
f
Then set the required set temperature on the thermostatic
valve.
Saving energy
The following recommended settings will result in the lowest en-
ergy consumption:
- 38 °C for hand washbasins, showers, bath
- 55 °C for kitchen sinks
Internal anti-scalding protection (qualified contractors)
If required, the qualified contractor can set a permanent temper-
ature limit, for example in nurseries, hospitals etc.
When supplying a shower, the appliance temperature setting
range must be adjusted by the qualified contractor to 55 °C or less.
Limiting it in this way prevents water from flowing out of the
appliance at temperatures which could cause injury.
Recommended setting for operation with a thermostatic valve
and water preheated by solar energy
f Set the temperature at the appliance to the maximum
f
temperature.
Following an interruption to the water supply
Material losses
!
To ensure that the bare wire heating system is not dam-
aged following an interruption to the water supply, the
appliance must be restarted taking the following steps.
f Disconnect the appliance from the power supply by
f
removing the fuses/tripping the MCBs.
f Open the tap for one minute until the appliance and
f
its upstream cold water inlet line are free of air.
f Switch the power back ON.
f
5.
Cleaning, care and maintenance
f Never use abrasive or corrosive cleaning agents. A damp
f
cloth is sufficient for cleaning the appliance.
f Check the taps regularly. Limescale deposits at the tap out-
f
lets can be removed using commercially available descaling
agents.
www.stiebel-eltron.com
6.

Troubleshooting

Problem
Cause
The appliance will not
There is no power.
start despite the DHW
valve being fully open.
The aerator in the tap or
the shower head is scaled
up or soiled.
The water supply has
been interrupted.
When hot water is being
The air detector detects
drawn off, cold water
air in the water. It switch-
flows for a short period.
es off the heating output
briefly.
The required tempera-
Internal anti-scalding
ture cannot be set.
protection is activated.
Note
After a power failure
Programming unit displays and selected settings are re-
tained following a power failure.
If you cannot remedy the fault, contact your qualified contractor.
To facilitate and speed up your request, provide the number from
the type plate (000000-0000-000000).
Remedy
Check the fuses/MCBs in
your fuse box/distribu-
tion board.
Clean and/or descale the
aerator or shower head.
Vent the appliance and
the cold water inlet line.
The appliance restarts
automatically after
1 minute.
The internal anti-scalding
protection can only be
adjusted by the qualified
contractor.
DHB-E LCD |
29