WARNING!
Spurting and overrun of coolants and lubricants. Ensure that
the cutting fluids are removed immediately after you have fin-
ished working. Close the stopcock of the coolant tank again.
On magnetic drilling machines with coolant ring, the stop must
be mounted to prevent rotation.
4.1

Fitting of the tool in the holder

4.1.1

Standard

Insert tool and firmly clamp with side screw.
4.1.2

Quick change

Push sleeve upwards and insert tool. Release the sleeve and check for secure attachment.
Standard
4.2

Placing the magnetic drill on the workpiece

INFORMATION
A sensor controls the possible magnetic holding force. With insufficient magnetic
holding force on the component, the magnetic drill can not be turned on.
To permit the magnetic drill to adhere properly to material that is to be drilled, the surface must
be clean and smooth. Loose rust, dirt or grease must be removed before mounting the mag-
netic drill; any welding beads or surface irregularities must be smoothened. Thin coats of paint
will not impair adhesion. Clean the magnet block as well if necessary. After switching the mag-
net on, shake the magnetic drill firmly to ensure that the magnetic drill is adhering properly. If it
is not, then check the condition of the surface of the material and that of the bottom of the mag-
net block.
