Wear safety shoes when you are transporting the magnetic drill, attaching or removing heavy
parts or transporting any parts.
1.5

Safety during operation

WARNING!
Before switching on the magnetic drill, make sure that:
there is no risk to persons,
no objects are damaged.
Avoid any unsafe work methods:
Make sure that your operation does not create a safety hazard.
The rules specified in these operating instructions must be observed during assembly,
operation, maintenance and repair.
Do not work on the magnetic drill if your concentration is reduced, for example, because
you are taking medication.
Observe the accident prevention regulations issued by your Employers Liability Insurance
Association or other supervisory authorities applicable to your company.
Inform the supervisor about all hazards or faults.
Remain by the magnetic drill until it has come to a complete stop.
Do not let the magnetic drill with electromagnet be unintentionally re-magnetised at the
work site.
Use the prescribed head protection. Ensure you wear close-fitting clothing and, if neces-
sary, a hairnet.
1.6

Electronics

Craftsman or industrial use
Have the machine and/or the electric equipment checked regularly. Immediately eliminate all
defects such as loose connections, defective wires, etc.
A second person must be present during work on live components to disconnect the power in
the event of an emergency. Disconnect the magnetic drill immediately if there is a malfunction
in the power supply!
Comply with the required inspection intervals in accordance with the factory safety directive,
operating equipment inspection.
The operator of the machine must ensure that the electrical systems and operating equipment
are inspected with regards to their proper condition, namely,
by a qualified electrician or under the supervision and direction of a qualified electrician,
prior to initial commissioning and after modifications or repairs, prior to recommissioning
and at set intervals.
The deadlines must be set so that arising, foreseeable defects can be detected in a timely man-
ner.
The relevant electro-technical rules must be followed during the inspection.
No check is required before first commissioning, if the manufacturer or installer has confirmed
to the operator that the electrical system and operating materials have been procured in
accordance with the stipulations of the accident prevention regulations.
1.7

Inspection deadlines

Technical or Industrial Use
Define and document the inspection deadlines for the machine in accordance with § 3 of the
Factory Safety Act and perform an operational risk analysis in accordance with § 6 of the Work
Safety Act.