1.3.1

Avoiding misuse

WARNING!
The use of the magnetic drill in the equipment with
electromagnet or permanent magnet in an inclined or vertical
position is only permitted if the magnetic drill is secured with
the securing belt supplied. If there is a power cut, or too great
a load, the magnetic force is not maintained. The magnetic
drill may drop and cause accidents.
Magnetic holding force
CAUTION!
Injury due to removal of the connection of the permanent magnet or electromagnet from
the substrate. The substrate must be magnetisable. The magnetic force is only present
on correctly prepared surfaces.
The adhesion of the magnetic drill to the substrate depends considerably on the
thickness of the material, the correctly prepared surface and the material itself. Smooth
out any unevenness, such as, for example, welding splatter and remove any lose rust,
dirt, grease and liquids.
INFORMATION
Working with stainless steel
Example for stainless steel: Stainless steel 1.4300 (V2A) has an austenitic microstructure and
is unmagnetic. Stainless steel 1.4016 has a ferritic microstructure and is magnetisable. The
higher the proportion of nickel or manganese in the steel, the greater the magnetic property and
the possible holding force of the magnetic drill onto the component.
In the case of non-magnetizable components, a magnetizable component must first be securely
attached to the stainless steel.
WARNING!
Injury due to unwanted removal of the magnet from the substrate. Only pull the mains
plug of the magnetic drill with electromagnet out of the socket if the magnet has been
shut down intentionally.
WARNING!
Do not work with the magnetic drill in environments at risk of explosion, in which
combustible liquids, gases or dusts are located. Electrical tools generate sparks which
may ignite the dust or vapours.
CAUTION!
When operating for a long time, the electromagnet heats up.
WARNING!
Strong Magnet. Persons with a pacemaker or other medical implants may not use the
magnetic drill. Carrying metal parts and watches is prohibited.