6. Operation
6.1 Description of the system
4
3
2
1
Fig. 30 Functional scheme VGS-141, -143, -145
Item
Component
1
Line to the injector
2
Differential pressure regulator
3
Electronics (option)
4
Clamp box (option)
5
Servomotor
6
Rate valve
7
Measuring tube
8
Vacuummeter
Sensor for the operation vacuum
9
(option)
10
Line from the vacuum regulator
11
Foot
17
Front hood (17) to take off, with swing-
18
out clear vision flap (18)
The rate valve is not a perfectly closing shut-off
Caution
valve!
5
6
8
7
9
10
11
Description
It regulates the difference of the pressures before and after the rate valve to a
constant value.
•
Adjusted dosing flow stays constant, even when the injector vacuum fluctuates.
•
with electronic vacuum sensor (option)
Measuring amplifier for the chlorine concentration Conex
•
amplifies the signal of the optional measuring cell
Adjusting the desired gas flow
•
manually with the hand wheel
or
•
automatically with an electrical servomotor (5) (option)
•
servomotor can optionally be equipped with a 4 - 20 mA signal input for
proportional control (no further electronics necessary)
Displays the gas flow
•
with magnetic detection of the floater position (option)
Displays the injector vacuum
•
with limit contacts (option)
For measuring the vacuum at the inlet of the gas dosing system