6 Putting into operation

6.5 Connecting the pneumatic system

A compressed air hose with a min. inner width of
housing by means of a G1/4" screw connection (not included). A compressed air shut-off valve in the supply
line is recommended. This allows the TCS-Compact to be quickly and simply depressurized if installation or
maintenance work are required.
Cleaning stroke cylinder
up
down
Z1
(Pneumatic motor)
Y1
4
2
12
14
12
14
5
1
3
Fig. 21
Connecting the pneumatic system
Pneumatic motor
M
1
S1
Clamp/cutter
open
closed
Z2
Y2
4
4
2
14
14
45°
14
14
12
5
5
3
1
ø
6 mm is required as a supply line. This is fastened to the
Vacuum output
Compressed air
S2
Y4
2
14
10
1
3
Y3
2
12
12
1
3
TCS-Compact
Return
Anti-spatter
fluid
Suction
Min. 6 bar