6 Putting into operation
NOTICE
• The clamping position in the direction of the reamer axis should be in the cylindrical part of the gas
nozzle.
Please note the clamping position (5) can vary depending on the gas nozzle type.
6.4 Setting up the pneumatic motor
1
9
1
Cleaning station
4
2
5
Welding torch
3
Gas nozzle clamping device
Fig. 19
Setting up the pneumatic motor
NOTICE
• Before you can set up the pneumatic motor in its final position, the welding torch has to be positioned
in the cleaning station.
• The motor stroke needs to be in the lower position (8) (stroke down).
2
Gas nozzle
6
M6x45 clamping screws
7
Reamer
AF6 Allen key
Fig. 18 Setting up the clamping position on page EN-25
Fig. 19 Setting up the pneumatic motor on page EN-26
TCS-Compact
3
4
5
6
7
8
8
Pneumatic motor (stroke down)
9
Motor bracket