System Description
2.6
Sensor model
Controller
Measuring range MR
Start of measuring range SMR
End of measuring range EMR
Gap between sensor and needle surface
Groove in injection needle
Linearity
Frequence response
Operating temperature
Storage temperature
Temperature stability
Max. pressure on sensor front face
Protection class
Length sensor cable
Material sensor cable
Signal output
Power supply
Electromagnetic compatibility (EMC)
The sensor LS04(01) is a product of the Robert Bosch GmbH.
FSO = Full Scale Output
The specified technical data apply for the reference material mild steel St37 DIN1.0037 at 20 °C.
NLS3181
Technical Data
Sensor cable,
Controller
LS04(01)
±1 %; < 5 % FSO by exchange
Sensor
-50 ... +150 °C (-58 ... +302 °F)
+10 ... +65 °C (+50 ... +149 °F)
-25 ... +75 °C (-13 ... +167 °F)
approximately 2000 bar
Sensor: IP 65 / Controller: IP 54
Standard: 0.25 m (±15 %) / Extension: 3 m (±15 %)
+24 VDC (9 VDC ... 36 VDC) / approximately 140 mA
LS04(02)
LS04(03)
NLC 3181-M
0.5 mm (0.016 ")
-0.45 mm
+0.05 mm
approx. 0.1 mm
groove width
≥ 3 mm
groove depth
≥ 0.5 mm
100 kHz (-3 dB)
0.015 % FSO / °C typ.
PTFE (teflon)
Standard ±5 V
EN 61326-1: 2006-10
DIN 61326-2-3: 2007-05
LS04(04)
approximately
3300 bar