Checking the measuring system setup:
1) Is the sensor adjusted for the application (target material)?
2) Are the sensor, cable length and electronics aligned (type and serial number)?
3) Is the sensor connected? Are the cable connections tight?
Connect the measuring system:
i
Matching power supply units for the controller are available as accessories.
The power supply and signal output are connected by the 8-pin built-in connector (DIN 45326). See the draw-
ing and table for the pin assignment. The controller contains an 8-pole cable socket for the user-side assem-
bly of your own connecting cable.
NLS3181
Operation
Set up the power supply to the controller.
Use the PC3/8 power supply and output cable (available as an accessory) or a user assembled cable.
Connect the output cable to the 8-pole built-in socket, see
plug.
Connect the output cable to a +24 VDC voltage supply.
Connect the measuring signal displays or recorders to the 8-pole built-in socket on the controller.
Switch on the power supply.
Let the measuring setup warm up for about 30 minutes.
Protect cables against pressure in pressurized rooms.