B2 Construction Form.
This construction form too allows direct coupling of
alternator and drive motor. Please follow the instruc-
tions below when assembling:
1) Check that the rotor is positioned correctly, as
illustrated in Figure 3a.
Fig. 3a
2) Remove rotor's locking components on the non-
drive end side.
3) Place the alternator next to the drive motor, as
illustrated in Figure 3b
Fig. 3b
4) Centre and secure the stator to the drive mo-
tor's flange, using suitable screws, as shown in
Figure 3c.
Fig. 3c
5) Centre and secure, using appropriate screws, the
coupling to the drive motor's flywheel working
through the air outlet, as indicated in Figure 3d.
Fig. 3d
FINAL CONTROLS
At the end of all the overwrite couplings it is
necessary to control the correct axial positioning; it
must be verified that between the end of non-drive
end side and the surface of axial clamping exists a
space of 3 mm.
- 20 -
4. USAGE:
Power cables connections should be car-
ried out by qualified personnel when the
machine is completely stopped and the power
cable is disconnected.
Voltage and output frequency
These alternators are designed to supply only the
voltage and frequency specified in the rating plate.