IDPlus 961-974 - HC
PAR. Description
Configuration of digital input DI1/polarity.
0= disabled; ±1= defrost; ±2= reduced set;
±3= AUX; ±4= door switch; ±5= external alarm;
±6= Stand-by; ±7= pressure switch; ±8= deep cooling;
H11
± 9= disable HACCP alarm logging.
NOTE:
• + sign indicates that the input is active if the contact is closed.
• - sign indicates that the input is active if the contact is open.
H12 Configuration of digital input DI2/polarity. Same as H11.
Configurability of digital output 1 (
H21
0 = disabled; 1 = compressor; 2 = defrost;
3 = fans; 4 = alarm; 5 = AUX; 6 = Stand-by.
H22 Configurability of digital output 2 (
H23 Configurability of digital output 3 (
Enable/disable buzzer.
H25
0 = Disabled; 4 = Enabled; 1-2-3-5-6-7-8 = not used.
Configurability of UP key.
0 = disabled;
2 = AUX;
H31
4 = stand-by;
6 = disable HACCP alarms;
H32 Configurability of DOWN key. Same as H31.
H42 Probe Pb2 present. n (0) = not present; y (1) = present.
H43 Probe Pb3 present. n (0) = not present; y (1) = present.
9IS54671.00 10 - 2018
).
). Same as H21.
). Same as H21.
1 = defrost;
3 = reduced set;
5 = reset HACCP alarms;
7 = deep cooling.
Range
UM
AP1 AP2 AP3 AP4
-9...9
num
2
-9...9
num
0
0...6
num
1
0...6
num
2
0...6
num
3
0...8
num
4
0...7
num
1
0...7
num
0
n/y
flag
y
n/y
flag
n
www.eliwell.com
0
4
2
0
0
0
1
1
1
2
5
2
3
3
3
4
4
4
1
1
1
0
0
0
y
y
y
y
n
n
37/40