USING THE COPYCARD
The CopyCard must be connected to the TTL serial port and allows the rapid programming of instrument parameters.
Access the "Installer" parameters by entering PA2, then scroll through the folders using
folder is displayed. Select it using
(for example UL).
set
• Upload (UL): select UL and press
instrument to the card. If the operation is successful, the display will show "y", otherwise it will show
"n".
• Format (Fr): This command is used to format the card (necessary when using it for the first time).
NOTE: formatting with the Fr parameter will delete all data present. This operation cannot be
reversed.
• Download: Connect the MFK with the device switched off. At power-on, data will automatically start
downloading from the USB key to the instrument. At the end of the lamp test, the display will show
"dLy" if the operation was successful and "dLn" if not.
NOTE: After the download, the instrument will use the newly uploaded map settings.
CONTROLLER ON/OFF
To switch the controller off, press and hold the
algorithms and defrost cycles are disabled and the text "OFF" will appear on the display.
DIAGNOSTICS
Alarms are always indicated by the buzzer (if present) and the alarm icon
To silence the buzzer, press and release any key, the relative icon will continue to flash.
NOTE: if alarm exclusion times have been set (see AL folder in the parameters table) the alarm will not be indicated.
9IS54671.00 10 - 2018
, scroll through the parameters using
set
. With this function, the programming parameters are uploaded from the
set
key for more than 5 seconds. In this condition, the adjustment
and
and
and select the function using
.
www.eliwell.com
until the FPr
19/40

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ewplus 961Ewplus 971Ewplus 974

Inhaltsverzeichnis