IDPlus 974 -HC PARAMETERS TABLE
NOTE: The ‛User' parameters are shown with grey background (
PAR. Description
SEt Temperature regulation SEtpoint.
COMPRESSOR (folder "CP")
diF diFferential. Compressor relay activation differential.
Higher SEt. Maximum value that can be assigned to the
HSE
setpoint.
LSE Lower SEt. Minimum value that can be assigned to the setpoint. -58.0...HSE °C/°F -50.0 -50.0 -50.0 -50.0
Temperature value to be added to the setpoint if reduced set
OSP
enabled (Economy function).
HC Regulation method. C (0) = Cool; H (1) = Heat
Controller switch-on time in the event of error probe.
If Ont=1 and OFt=0, the compressor will always stay on;
Ont
If Ont=1 and OFt>0, it operates in duty cycle mode.
Controller switch-off time in the event of error probe.
If OFt=1 and Ont=0, the controller will always stay OFF;
OFt
If OFt=1 and Ont>0, it operates in duty cycle mode.
dOn Compressor relay activation delay after request.
dOF Delay after switching off and subsequent switch-on.
dbi Delay between two consecutive compressor switch-ons.
Delay in activating outputs after the instrument is switched on
OdO
or after a power outage. 0 = not active.
dCS "Blast Chilling" setpoint.
9IS54671.00 10 - 2018
).
Range
UM
AP1 AP2 AP3 AP4
LSE...HSE °C/°F 0.0
0.1...30.0 °C/°F 2.0
LSE...302 °C/°F 99.0 99.0 99.0 99.0
-30.0...30.0 °C/°F 3.0
C/H
flag
C
0...250
min
0
0...250
min
1
0...250
s
0
0...250
min
0
0...250
min
0
0...250
min
0
-58.0...302 °C/°F 0.0
www.eliwell.com
0.0
0.0
0.0
2.0
2.0
2.0
0.0
0.0
3.0
C
C
C
0
0
0
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0.0