PAR. Description
dCS "Blast Chilling" setpoint.
tdC "Blast Chilling" duration.
dCC Defrost activation delay after a "Blast Chilling Cycle".
DEFROST (folder "dEF")
dit Interval between the start of two consecutive defrost cycles.
Selects the count mode for the defrost interval.
0 = compressor running time;
dCt
1 = device running time;
2 = every time the compressor stops, a defrost cycle is carried
out.
dOH Delay preceding start of first defrost after call.
dEt Defrost timeout; determines the maximum defrost duration.
Determines whether or not the instrument must defrost at
dPO
power-up. n (0) = no; y (1) = yes.
ALARMS (folder "AL")
Can be used to select absolute (Att=0) or relative (Att=1)
Att
values for HAL and LAL parameters.
AFd Alarm differential.
HAL Maximum temperature alarm.
LAL Minimum temperature alarm.
PAO Alarm exclusion time on switching back on after power outage.
dAO Temperature alarm exclusion time after defrost.
OAO Alarm signaling delay after digital input disabling.
9IS54671.00 10 - 2018
Range
UM
AP1 AP2 AP3 AP4
-58.0...302 °C/°F 0.0
0...255
min
0
0...255
min
0
0...250
hours
6
0/1/2
num
1
0...59
min
0
1...250
min
1
n/y
flag
n
0/1
flag
0
1.0...50.0 °C/°F 2.0
LAL...302 °C/°F 150
-58.0...HAL °C/°F -50.0 -50.0 -50.0 -50.0
0...10
hours
0
0...999
min
0
0...10
hours
0
www.eliwell.com
0.0
0.0
0.0
0
0
0
0
0
0
0
0
8
1
1
1
0
0
0
1
1
30
n
n
n
0
0
0
2.0
2.0
2.0
150
150
50.0
0
0
0
0
0
0
0
0
0
25/40

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ewplus 961Ewplus 971Ewplus 974

Inhaltsverzeichnis