IDPlus 961-974 - HC
PAR. Description
Configuration of digital input DI1/polarity.
0 = disabled;
±1 = defrost;
±3 = AUX;
±5 = external alarm;
H11
±7 = pressure switch;
± 9 = disable HACCP alarm logging.
NOTE:
• + sign indicates that the input is active if the contact is closed.
• - sign indicates that the input is active if the contact is open.
Configurability of digital output 1 (
0 = disabled;
H21
1 = compressor;
3 = reserved;
5 = AUX;
Configurability of UP key.
0 = disabled;
H31
2 = AUX;
4 = stand-by;
6 = disable HACCP alarms;
H32 Configurability of DOWN key. Same as H31.
Probe Pb3 present.
H43
n (0) = not present;
rEL Device version. Read-only parameter.
tAb table of parameters. Reserved: read-only parameter.
9IS54671.00 10 - 2018
±2 = reduced set;
±4 = door switch;
±6 = Stand-by;
±8 = deep cooling;
).
2 = defrost;
4 = alarm;
6 = Stand-by.
1 = defrost;
3 = reduced set;
5 = reset HACCP alarms;
7 = deep cooling.
y (1) = present.
Range
UM
AP1 AP2 AP3 AP4
-9...9
num
2
0...6
num
1
0...7
num
1
0...7
num
0
n/y
flag
n
/
/
/
/
/
/
www.eliwell.com
2
0
0
1
1
1
0
0
1
0
0
0
n
n
y
/
/
/
/
/
/
29/40