Eliwell EWPlus 902 Handbuch Seite 24

Elektronische regler für kühleinheiten
Inhaltsverzeichnis

Werbung

IDPlus 961-974 -HC
IDPlus 961 -HC PARAMETERS TABLE
NOTE: The ‛User' parameters are shown with grey background (
PAR. Description
SEt Temperature regulation setpoint.
COMPRESSOR (folder "CP")
diF diFferential. Compressor relay activation differential.
Higher SEt. Maximum value that can be assigned to the
HSE
setpoint.
Lower SEt. Minimum value that can be assigned to the set
LSE
point.
Temperature value to be added to the setpoint if reduced set
OSP
enabled (Economy function).
HC Regulation method. C (0) = Cool; H (1) = Heat
Controller switch-on time in the event of error probe.
Ont
If Ont=1 and OFt=0, the compressor will always stay on;
If Ont=1 and OFt>0, it operates in dutycycle mode.
Controller switch-off time in the event of error probe.
OFt
If OFt=1 and Ont=0, the controller will always stay OFF;
If OFt=1 and Ont>0, it operates in dutycycle mode.
dOn Compressor relay activation delay after request.
dOF Delay after switching off and subsequent switch-on.
dbi Delay between two consecutive compressor switch-ons.
Delay in activating outputs after the instrument is switched on
OdO
or after a power outage. 0 = not active.
9IS54671.00 10 - 2018
).
Range
UM
AP1 AP2 AP3 AP4
LSE...HSE °C/°F 0.0
0.1...30.0 °C/°F 2.0
LSE...302 °C/°F 140
-58.0...HSE °C/°F -55.0 -55.0 -55.0 -10.0
-30.0...30.0 °C/°F 3.0
C/H
flag
C
0...250
min
0
0...250
min
1
0...250
s
0
0...250
min
0
0...250
min
0
0...250
min
0
www.eliwell.com
0.0
0.0
-2.0
2.0
2.0
0.1
140
140
5.0
3.0
0.0
0.0
C
H
C
0
0
0
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0