Herunterladen Inhalt Inhalt Diese Seite drucken

Operation; Switch-On / Switch-Off; Switch-On; Switch-Off - Bosch FSA 500 Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für FSA 500:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
en
28 | FSA ��� | Operation
5.

Operation

�.1

Switch-on / switch-off

�.1.1

Switch-on

!
To avoid the formation of condensation, allow the
FSA 500 to adjust to ambient temperature before
switching on the FSA 500.
Briefly press the ON/OFF switch (refer to Fig. 1,
Pos. 4).
 LED A flashes (green) after 4 seconds.
"
FSA 500 is ready for operation.
�.1.2

Switch-off

Manual switch-off
Press the ON/OFF switch for approx. 3 seconds.
 LED A off.
"
FSA 500 switched off.
Automatic switch-off in battery mode
An acoustic warning signal sounds if the FSA 500
has not been operated for 10 minutes in battery
mode. The FSA 500 is then switched off automatically
after 30 seconds. After turning the FSA 500 back
on, the desired test step can be recalled in the
FSA 500 CompacSoft [plus] software.
|
1 689 989 115
2011-09-20
�.2

Notes on measurement

DANGER – Risk of electric shock if measure-
ments are taken on motor vehicles without
connecting cable B–!
Measurements taken with connecting cable
B– not connected to vehicle ground or the
negative post of the battery will result in
injury, heart failure or fatal electric shocks.
For all measurements, connect the
FSA 500 by way of connecting cable B – to
vehicle ground or the negative post of the
battery.
DANGER – Risk of electric shock from ex-
cessively high measurement voltage.
The measurement of voltages in excess
of 200 V using Multi measurement leads
CH1 / CH2 will result in injury, heart failure or
fatal electric shocks.
Multi measurement leads CH1 / CH2 are
only to be used for measuring voltages up
to max. 200 V.
Never use Multi measurement leads CH1 /
CH2 to measure mains or similar voltages.
!
The FSA 500 is not to be used for checking isolation
from the supply on electric and hybrid vehicles.
i
Measurement deviations may occur during battery
charging.
i
Battery operation is not possible during 24 h meas-
urements (battery life < 4 h). The FSA 500 must then
be provided with power from the power supply unit.
The DCU 130 or PC/laptop must also stay enabled
during that time (e.g. sleep mode in Windows oper-
ating system should not be set).
�.�

Software update

i
Proceed as described in Section 4.3 to update the
software.
Robert Bosch GmbH

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis