�� | FSA ��� | Technical data
8.
Technical data
8.1
Dimensions and weights
Property
Dimensions (W x H x D)
Weight (without accessories)
8.2

Specifications

Property
Rated voltage U(V)
Rated power P(W)
Degree of protection
8.�
Temperature, humidity and

atmospheric pressure

8.�.1
Ambient temperature
Property
Storage and transportation
Operation
Measurement accuracy
Battery charging temperature
8.�.2
Humidity
Property
Storage and transportation
Operation
Measurement accuracy
8.�.�
Atmospheric pressure
Property
Storage and transportation
Operation (at 25 °C and 24 h)
Measurement accuracy
8.4

Noise emissions

< 70 dB(A)
8.�
Power supply unit
Property
Frequency
Input voltage (AC)
Input current
Output voltage (DC)
Output current
|
1 689 989 115
2011-09-20
Value/Range
200 x 280 x 110 mm
7.9 x 11.0 x 4.3 inch
1,5 kg
3.3 lb
Value/Range
19 DC
60
IP 30
Value/Range
5 °C – 40 °C
41 °F – 104 °F
5 °C – 40 °C
41 °F – 104 °F
10 °C – 35 °C
50 °F – 95 °F
0 – 45°C
Value/Range
30 % – 60 %
20 % – 80 %
30 % – 60 %
Value/Range
700 hPa – 1060 hPa
700 hPa – 1060 hPa
700 hPa – 1060 hPa
Value/Range
50 – 60 Hz
100 – 240 V~
1,5 A
19 V
3,7 A
8.6
Battery
Property
Battery life
Charging time for battery capacity
> 70 %
(with battery flat and FSA 500
switched off; charging time increas-
es with parallel measurements)
8.7

Bluetooth Class 1 and 2

Radio link
Free field workshop environment
For measurements in vehicle engine
compartment
Tab. 1:
Bluetooth Class 1
Radio link
Free field workshop environment
For measurements in vehicle engine
compartment
Tab. 2:
Bluetooth Class 2
8.8
Signal generator
Function
Amplitude
Signal forms
Frequency range
Max. output current
Impedance
Symmetry
Curve generation
Short-circuit proof with respect
to interference voltage, static
Short-circuit proof with respect
to interference voltage, dynamic
Additionally:
R
Automatically activated filters and attenuators
for enhanced signal quality.
R
Automatic shut-off in the case of short circuit,
detection of interference voltage on starting signal
generator.
Value/Range
< 4 h
< 1 h
Minimum range
30 m
10 m
Minimum range
3 m
1 m
Specification
- 10 V - 12 V
(load < 10 mA) to ground
DC, sinusoidal, triangular,
square-wave
1 Hz - 1 kHz
75 mA
approx. 60 Ohm
10 % - 90 %
(triangular, square-wave)
Output rate up to
100000 values/s,
resolution 8 bit,
Y full range adjustable
(bit), unipolar / bipolar
operation
< 50 V
< 500 V / 1 ms