Herunterladen Inhalt Inhalt Diese Seite drucken

Operation; Power Supply; Switching Unit On / Off; Switch-On - Bosch BEA 060 Originalbetriebsanleitung

Abgasmessgerät für benzinfahrzeuge
Vorschau ausblenden Andere Handbücher für BEA 060:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
en
| 22 | BEA 060 | Operation
4.

Operation

!
Only transport the BEA 060 in an upright position.
If the BEA 060 is tilted during transportation,
condensate may escape and damage the
measurement chamber. Select the installation
location such that the BEA 060 cannot fall down
and is correctly positioned (carrying handle at top).
4.1

Power supply

The power supply is obtained from the lighting system.
The BEA 060 can be operated at between 100 V and
240 V, 50/60 Hz.
i
The BEA 060 can also be supplied with power
by way of the vehicle battery using the cigarette
lighter socket connecting cable (special accessory).
Refer to fig. 1, pos. 12 for connection.
!
Prior to start-up, make sure the lighting system
voltage coincides with the set BEA 060 voltage. If
the BEA 060 is operated outdoors, it is advisable
to use a voltage source protected by a residual
current-operated circuit breaker. The unit is only to
be operated in dry conditions.
!
To avoid the formation of condensation, allow the
BEA 060 to adjust to ambient temperature before
switching on the BEA 060.
i
The details of the power supply are given on
a sticker on the back of the BEA 060.
|
1 689 989 182
2020-06-24
4.2

Switching unit on / off

4.2.1

Switch-on

1. Plug in the power cord at the BEA 060 and attach
the power cord at the holes (fig. 1, pos. 4) with
a cable tie to provide strain relief.
2. Connect the BEA 060 to the lighting system by way
of the power cord.
3. Press the On/Off button.
"
Alternate orange and green flashing of LED (fig. 1,
pos. 16).
4.2.2

Switch-off

To keep contamination of the BEA 060 to a minimum,
it is advisable to flush residual gas out of the
BEA 060 prior to switch-off with the pump running.
The sampling probe must be in the open air for this
purpose.
i
First exit from the exhaust gas test step and wait
for completion of pump run-on. Then switch off the
BEA 060.
Press the On/Off button for three seconds.
"
The LED (fig. 1, pos. 16) goes out, the BEA 060 is
switched off.
4.3
Start-up of BEA 060 in stand-alone
mode
The following description of installation of SystemSoft
BEA-PC, as well as BEA 060 configuration, only apply
to BEA 060 stand-alone mode.
4.3.1

Installing SystemSoft BEA-PC

i
Heed the system prerequisites before starting
installation.
i
Only plug in the Bluetooth USB adapter when
prompted to do so during software installation.
1. Close all open applications.
2. Insert the "SystemSoft BEA-PC" DVD in the
DVD drive.
3. Start "Windows Explorer".
4. Start 'D:\RBSETUP.EXE' (D = DVD drive letter).
 BEA set-up is started.
5. Confirm with <Continue>.
6. Heed and follow the instructions on the screen.
7. Re-start the PC/Laptop to successfully conclude
installation.
"
BEA is installed.
Robert Bosch GmbH