Herunterladen Inhalt Inhalt Diese Seite drucken

Ogólne Bezpieczeństwo Podczas Spawania Łukowego - Telwin Superior Tig 422 AC/DC-HF/LIFT Bedienungsanleitung

Mit invertertechnik
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 20
POLSKI
2. WPROWADZENIE I OGÓLNY OPIS ........................................................................80
2.1 WPROWADZENIE ............................................................................................80
2.2 AKCESORIA NA ŻĄDANIE ...............................................................................80
3. DANE TECHNICZNE ................................................................................................81
3.1 TABLICZKA ZNAMIONOWA ..............................................................................81
3.2 POZOSTAŁE DANE TECHNICZNE ..................................................................81
4. OPIS SPAWARKI .....................................................................................................81
4.1 SCHEMAT BLOKOWY .....................................................................................81
4.2.1 Panel tylny ...............................................................................................81
4.2.2 Panel przedni RYS. D1 ...........................................................................81
4.2.3 Panel przedni RYS. D2 ...........................................................................82
SPERSONALIZOWANYCH ...............................................................................83
5. INSTALACJA ............................................................................................................83
5.1 PRZYGOTOWANIE ...........................................................................................83
5.1.1 Montaż przewodu powrotnego-zacisk kleszczowy ..................................83
5.1.2 Montaż przewodu spawania-uchwyt elektrody ........................................83
SPAWARKI
INWERTEROWE
TIG I METODĄ MMA, PRZEWIDZIANE DO UŻYTKU PRZEMYSŁOWEGO I
PROFESJONALNEGO.
Uwaga: W dalszej części niniejszej instrukcji używany jest termin"spawarka".

1. OGÓLNE BEZPIECZEŃSTWO PODCZAS SPAWANIA ŁUKOWEGO

Operator powinien być odpowiednio przeszkolony w zakresie bezpiecznego
używaniu spawarki, jak również poinformowany o zagrożeniach związanych
z procesami spawania łukowego, odpowiednich środkach ochronnych oraz
procedurach awaryjnych.
(Przejrzeć również "SPECYFIKACJĘ TECHNICZNĄ IEC lub CLC/TS 62081":
INSTALACJA I UŻYWANIE SPRZĘTU DO SPAWANIA ŁUKOWEGO).
- Unikać bezpośrednich kontaktów z obwodem spawania; w niektórych
okolicznościach napięcie jałowe wytwarzane przez generator może być
niebezpieczne.
- Podłączanie przewodów spawalniczych, operacje mające na celu kontrolę
oraz naprawa powinny być wykonane po wyłączeniu spawarki i odłączeniu
zasilania urządzenia.
- Przed wymianą zużytych elementów uchwytu spawalniczego należy wyłączyć
spawarkę i odłączyć zasilanie.
- Wykonać instalację elektryczną zgodnie z obowiązującymi normami oraz
przepisami bezpieczeństwa i higieny pracy.
- Spawarkę należy podłączyć wyłącznie do układu zasilania wyposażonego w
uziemiony przewód neutralny.
- Upewnić się, że wtyczka zasilania jest prawidłowo podłączona do uziemienia
ochronnego.
- Nie używać spawarki w środowisku wilgotnym lub mokrym lub też podczas
padającego deszczu.
- Nie używać kabli z uszkodzoną izolacją lub poluzowanymi połączeniami.
- Nie spawać pojemników, kontenitorów lub przewodów rurowych, które
zawierają lub zawierały ciekłe lub gazowe substancje łatwopalne.
- Nie stosować rozpuszczalników chlorowanych do materiałów czystych i nie
przechowywać w ich pobliżu.
- Nie spawać zbiorników pod ciśnieniem.
- Usunąć z obszaru pracy wszelkie substancje łatwopalne(np. drewno, papier,
szmaty, itp.).
- Upewnić sie, czy w pobliżu łuku jest odpowiednia wentylacja powietrza lub czy
znajdują się odpowiednie środki służące do usuwania oparów spawalniczych;
należy systematycznie sprawdzać, aby ocenić granice działania oparów
spawalniczych w zależności od ich składu, stężenia i czasu trwania samego
procesu spawania.
- Przechowywać butlę z dala od źródeł ciepła i chronić przed bezpośrednim
działaniem promieniowani słonecznych( jeżeli używana).
- Zastosować
odpowiednią
obrabianym
przedmiotem
metalowymi, które znajdują się w pobliżu (są dostępne).
W tym celu należy nosić rękawice ochronne, obuwie ochronne, nakrycia
głowy i odzież ochronną oraz stosować pomosty lub chodniki izolacyjne.
- Należy zawsze chronić oczy za pomocą odpowiednich szkieł przyciemnianych
z filtrem UV, zamontowanych na maskach lub przyłbicach spawalniczych.
Nosić odpowiednią ognioodporną odzież ochronną, unikając narażenia na
działanie promieniowania nadfioletowego i podczerwonego, wytwarzanego
przez łuk; rozszerzyć zabezpieczenie na inne osoby znajdujące sie w pobliżu
łuku za pomocą osłon lub zasłon nie odbijających.
- Hałaśliwość: Jeżeli w wyniku operacji spawania szczególnie intensywnych
zostanie stwierdzony poziom osobistego narażenia codziennego (LEPd)
równy lub wyższy od 85db(A), należy zastosować odpowiednie środki
ochrony osobistej.
- Przepływający
prąd
spawania
elektromagnetycznych (EMF) zlokalizowanych w pobliżu obwodu spawania.
Pola elektromagnetyczne mogą nakładać się na funkcjonowanie aparatury
medycznej (np. Pace-maker, aparaty tlenowe, protezy metalowe, itp.).
Należy zastosować odpowiednie środki ochronne w stosunku do osób
stosujących te urządzenia. Na przykład zakaz dostępu do strefy, w której
używana jest spawarka.
Niniejsza spawarka spełnia wymagania standardu technicznego produktu
przeznaczonego do użytku wyłącznie w pomieszczeniach przemysłowych i w
celach profesjonalnych. Nie jest gwarantowana zgodność z podstawowymi
PRZEZNACZONE
DO
SPAWANIA METODĄ
izolację
elektryczną
pomiędzy
i
ewentualnymi
uziemionymi
powoduje
powstawanie
SPIS TREŚCI
str.
5.2 USTAWIENIE SPAWARKI .................................................................................83
5.3 PODŁĄCZENIE DO SIECI ................................................................................83
5.3.1 Wtyczka i gniazdo ...................................................................................83
5.4 PODŁĄCZENIA OBWODU SPAWANIA ............................................................83
5.4.1 Spawanie metodą TIG .............................................................................83
5.4.2 Spawanie metodą MMA .........................................................................83
6. SPAWANIE: OPIS PROCESU ..................................................................................83
6.1 SPAWANIE TIG .................................................................................................83
6.1.1 Zajrzenie HF i LIFT ..................................................................................83
6.1.2 Spawanie metodą TIG DC ......................................................................84
6.1.3 Spawanie metodą TIG AC .......................................................................84
6.1.4 Proces spawania .....................................................................................84
6.2 SPAWANIE METODĄ MMA ...............................................................................84
6.2.1 Proces spawania .....................................................................................84
7. KONSERWACJA ......................................................................................................84
7.1 RUTYNOWA KONSERWACJA .........................................................................84
7.1.1 KONSERWACJA UCHWYTU SPAWALNICZEGO ..................................84
7.2 NADZWYCZAJNA KONSERWACJA .................................................................84
8. WYSZUKIWANIE USTEREK ...................................................................................84
wymogami dotyczącymi ekspozycji człowieka na pola elektromagnetyczne w
otoczeniu domowym.
Operator musi stosować się do następujących zaleceń, umożliwiających
zredukowanie ekspozycji na pola elektromagnetyczne:
-
Przymocuj dwa przewody spawalnicze możliwie jak najbliżej siebie.
-
Zwracaj uwagę, aby głowa i tułów znajdowały się najdalej możliwie od
obwodu spawania.
-
Nie owijaj nigdy przewodów spawalniczych wokół ciała.
-
Nie spawaj podczas przebywania w zasięgu obwodu spawania. Zwracaj
uwagę, aby oba przewody znajdowały się z tej samej strony ciała.
-
Podłącz przewód powrotny prądu spawania do spawanego przedmiotu,
najbliżej jak tylko jest to możliwe do spawanego złącza.
-
Nie spawaj w pobliżu spawarki, nie siadaj lub opieraj się o nią podczas
wykonywania tej operacji, (minimalna odległość: 50cm).
-
Nie pozostawiaj przedmiotów ferromagnetycznych w pobliżu obwodu
spawania.
-
Minimalna odległość d= 20cm (Rys. O).
- Aparatura klasy A:
Niniejsza spawarka spełnia wymagania standardu technicznego produktu
przeznaczonego do użytku wyłącznie w pomieszczeniach przemysłowych
i w celach profesjonalnych. Nie jest gwarantowana zgodność z wymogami
dotyczącymi pola elektromagnetycznego w budynkach domowych oraz w
tych, które są podłączone bezpośrednio do sieci zasilającej niskim napięciem
budynki przeznaczone do użytku domowego.
DODATKOWE ŚRODKI OSTROŻNOŚCI
- OPERACJE SPAWANIA:
- W otoczeniu o zwiększonym zagrożeniu szoku elektrycznego;
- W miejscach graniczących;
- W obecności materiałów łatwopalnych lub wybuchowych.
NALEŻY zapobiegawczo poddawać ocenie "Odpowiedzialnego fachowca" i
wykonywać zawsze w obecności innych osób przeszkolonych do interwencji
w przypadku awarii.
NALEŻY zastosować techniczne środki zabezpieczające, opisane w punktach
5.10; A.7; A.9. "SPECYFIKACJI TECHNICZNEJ IEC lub CLC/TS 62081".
- ZABRANIA SIĘ spawania operatorom znajdującym sie nad podłożem,
z
wyjątkiem
bezpieczeństwa.
- NAPIĘCIE
POMIĘDZY
SPAWALNICZYMI: podczas pracy z większą ilością spawarek na jednym
przedmiocie lub na kilku przedmiotach połączonych elektrycznie może
powstawać niebezpieczna suma napięć jałowych pomiędzy dwoma różnymi
uchwytami elektrody lub uchwytami spawalniczymi, o wartości mogącej
osiągać podwójną wartość graniczną dopuszczalną.
Doświadczony
odpowiedniego
zastosowanie odpowiednich środków zabezpieczających, jak w punkcie 5.9
"SPECYFIKACJI TECHNICZNEJ IEC Lub CLC/TS 62081".
elektrodą,
częściami
POZOSTAŁE ZAGROŻENIA
- NIEWŁAŚCIWE UŻYWANIE: używanie spawarki do jakiejkolwiek obróbki
odmiennej od przewidzianej jest niebezpieczne (np. rozmrażanie przewodów
rurowych instalacji wodnej).
2. WPROWADZENIE I OGÓLNY OPIS
2.1 WPROWADZENIE
Niniejsza spawarka jest źródłem prądu przeznaczonym do spawania łukowego,
zrealizowanym specjalnie do spawania elektrod otulonych (rutylowe, kwasowe,
zasadowe) metodą TIG (DC) (AC/DC), z zajarzeniem HF lub LIFT oraz do spawania
metodą MMA.
Specyficzne parametry tej spawarki (INWERTEROWA), takie jak prędkość oraz
ciśnienie regulacji powodują, że jakość spawania jest bardzo wysoka.
Regulacja systemu "inverter" na wejściu linii zasilania (pierwotny) powoduje ponadto
drastyczną redukcję objętości zarówno transformatora jak i reaktancji, umożliwiając
skonstruowanie spawarki o objętości i wadze ekstremalnie umiarkowanych,
podkreślając zalety łatwej obsługi i przenośności.
pól
2.2 AKCESORIA NA ŻĄDANIE:
- Zestaw do spawania metodą MMA.
- Zestaw do spawania metodą TIG.
- Adapter do butli gazowej Argon.
- Reduktor ciśnienia.
- Uchwyt spawalniczy TIG.
- Maska spawalnicza samościemniająca: z filtrem stałym lub regulowanym.
- Przewód powrotny prądu spawania z zaciskiem uziemiającym.
- Zdalne sterowanie w trybie ręcznym na 1 potencjometr.
- Zdalne sterowanie w trybie ręcznym na 2 potencjometry.
- 80 -
ewentualnych
przypadków
UCHWYTAMI
ELEKTROD
koordynator
powinien
dokonać
przyrządu,
celem
zbadania
str.
zastosowania
platform
LUB
UCHWYTAMI
pomiaru
za
pomocą
zagrożenia
i
umożliwić

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis