Herunterladen Inhalt Inhalt Diese Seite drucken

Special Functions; A) Configuring The Public Access Prefix - Conrad Electronic Rm50 Bedienungsanleitung

Funk-rauchmelde-system (alarmwählgerät; funk-rauchmelder )
Vorschau ausblenden Andere Handbücher für RM50:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

10. Special Functions

a) Configuring outside line access
While operating the alarm dialler at the subscriber's extension, it could be necessary to access an
outside line by dialling a zero first. It should be borne in mind (also refer to section 6. c), that in the
event of a power failure, the telephone system mostly fails, too and outside line access is not possible.
Direct connection to the telephone network without outside line access is a more secure operation,
where possible.
Outside line access of the alarm dialler "AW50", if activated, dials a zero before the
number. Telephone systems with other outside access numbers cannot be used.
For switching outside access on or off, proceed as follows:
1. Activate programming mode
• Press "Prg" key
• Red LED "Mode" lights up, entry level 1 is active
2. Select "Outside line access" mode
• Press key "Mod" , then press key "4"
• Red LED "Mode" flashes, entry level 2 is active
• Key "1" switches the outside line access off
• Key "2" switches the outside line access on
3. Terminate "Outside line access" mode
• The programming mode is terminated automatically after 10 seconds or by pressing the "#"key
on the alarm dialler. The last setting for outside line access is saved here.
• The red LED "Mode" goes off, the programming mode is terminated and the alarm dialler returns
to the normal operation.