2 Output logic setting
This sets the logic for the BCD data, sign, and READY signal. Each can be set independently. See "3-4-4. Output Logic
Setting" (P. 92) for details.
For individual input:
BCD data: Positive logic
Sign:
Positive logic
READY signal:
Negative logic
For AUTO input:
• • • 1 1 2 • • • • •
3 Output mode setting
There are several formats for BCD data that is output.
• Constant output mode
• Latch mode
• 3-state mode
• High-speed output mode
In addition, the timing after data is refreshed until it is output can be changed (except for high-speed mode). See "3-4-5. Output
Mode Setting" (P. 96) for details.
For individual input:
Constant output mode, no
refresh time
For AUTO input: • • • • • • 1 0 0 • •
Is positive
(Yes)
Is positive logic
logic used for
used for the
the BCD
sign bit?
data?
+ n 0
For example:
– n 1
0 n 0000
7 n 0111
0 = ON,
1 = OFF
(Yes)
Is it necessary to
always output
(No)
BCD data?
Is negative logic
(Yes)
used for the
READY signal?
Data is settled
n 0
Data is undefined
n 1
(No)
(No)
Is the data to be saved
(No)
when necessary?
(Yes)
Setting unnecessary
(Yes)
(Initial value)
"LGC" menu setting is necessary.
(For AUTO input, set the number in
the fourth through sixth digits.)
Setting unnecessary
(Initial value)
"
Mod" menu setting is necessary.
(For AUTO input, set the number in
the seventh through ninth digits.)
81