The READY signal invalid time setting can be changed in units of 1ms. (Refer to the initial setting in section "3-4-5. Output
Mode Setting.")
However, as was described in item (2), because the time T
T
is also affected by the operating conditions. Therefore, even if the value for the prohibited time is input in units of 1 ms, the
2
actual time T
does not change in units of 1 ms.
2
For 1st axis input and the LZ51-B expansion unit
Set time
None
1 to 8 ms
9ms
10 to 16 ms
17ms
18 to 20 ms
For 2nd axis input and the LZ51-B and LZ51-K/LZ51-R expansion units
Set time
None
1 to 13 ms
14 ms
15 to 20 ms
changes according to the operating conditions, the prohibited time
1
Actual READY signal invalid time T
About 50 µs
About 8 ms
About 8 ms or about 16 ms
About 16 ms
About 16 ms or about 24 ms
About 24 ms
Actual READY signal invalid time T
About 50 µs
About 13 ms
About 13 ms or about 26 ms
About 26 ms
Data valid time T
2
About 8 ms
About 8 ms
About 8 ms or about 16 ms
About 16 ms
About 16 ms or about 24 ms
About 24 ms
Data valid time T
2
About 13 ms
About 13 ms
About 13 ms or about 26 ms
About 26 ms