15
Repairs must only be carried out by
authorised professionals.
If a fault in your appliance cannot be
rectified with the aid of this table,
please contact the Central Customer
Service Department at CLAGE.
Please have the details of the
typeplate at hand.
CLAGE GmbH
Central Customer Service
Pirolweg 1 - 5
D - 21337 Lüneburg
Tel.: +49 (0)4131• 89 01-40
Fax: +49 (0)4131• 89 01-41
E-Mail: service@clage.de
16
These guarantee terms shall be governed solely after purchase and use of our appliances in the Federal Republic of Germany.
Abroad, the corresponding guarantee terms are based on the contractual General Terms of Sale and Delivery resp. on the statutory
terms of guarantee of each country. Statutory warranty rights (after performance, rescission, liability and reduction) are not
affected by this guarantee. This guarantee statement shall be considered as voluntary from the manufacturer.
From the date of purchase, CLAGE grants a 24 months' Guarantee period for your privately used hot water appliance and
12 months for commercial use on condition that the Certificate of guarantee delivered with the unit is duly completed, stamped
and dated by the dealer. The latter shall be presented together with the purchase document when claiming under guarantee.
We recommend that the guarantee certificate card be sent to CLAGE Lueneburg for registration after installation of the unit.
The guarantee does not cover damage or malfunctions due to the build-up of scale, frost, chemicals or electromechanical process,
from incorrect use, incorrect installation, dirt in the inlet and outlet pipes, non-compliance with the operating instructions or
unauthorised modification of the heater. Furthermore, the guarantee shall not cover any normal abrasion of the appliance.
In the event of a damage/claim, we are to be informed in writing within 14 days after recognition of the fault. After receipt, we
check if a legitimate guarantee claim is justified. If notice of defects has been given in good time and is justified, CLAGE shall
decide how the damage/claim is to be rectified, either by an authorised after-sales partner or by CLAGE central customer service.
D D
G G B B

Trouble-shooting and service

Your instantaneous water heater DLX was manufactured conscientiously and checked
several times before delivery. Should malfunctions nevertheless occur, attempt first to
remedy the problem with reference to the following table. In doing so, you will avoid
the unnecessary expense of customer service assistance.
Problem
Water stays cold,
bar chart display does
not light up
Appliance does not heat
Flow rate of hot water
too weak
Hot water flow is too low
Selected temperature
is not reached
No response
upon key press
Guarantee terms
18
Cause
Solution
Master fuse
Renew or
tripped
aktivate fuse
Control system
Switch fuse off and on.
has switched off
If neccessary contact
customer service
Outlet fitting dirty
Clean shower
or calcified
head, perlator or
sieves
Fine filter dirty
Clean fine filter
or calcified
Flow is limited
Adapt flow control
Excessive water
Reduce water flow
flow (winter?)
rate at the outlet or
adapt flow control
Hood is not
Refit the hood
fitted properly
properly