15. Trouble-shooting and service

The following table will help you to determine and rectify the reasons for possible problems. If you cannot rectify the
fault with the aid of this table, please contact:
CLAGE GmbH
Central customer service
Pirolweg 1–5
21337 Lüneburg
Germany
Fon: +49 (0) 4131 – 89 01-40
Fax: +49 (0) 4131 – 89 01-41
E-mail: service@clage.de
Internet: www.clage.de
We can either give you the name and address of an authorised customer service company or repair the heater oursel-
ves. In the latter case, please send in the heater (at your cost and risk) with details of the problem and a copy of the
sales invoice.
Fault
Cause
no water flows
water supply is turned off
the jet regulator is not fitted
water flows more
water pressure is not sufficient
slowly than expected
dirt in the pipes
the heater switches
water pressure is varying,
itself on and off
flow rate is too low
electric supply incorrect
circuit breaker has tripped
water remains cold,
safety thermal cut-out has tripped
although the appli-
faulty heating element
ance switches on
one phase is not connected
water connections mixed up
appliance does not
switch on and the
water pressure is not sufficient
water remains cold
dirt in the pipes
water pressure varies
hot water tempera-
ture varies
supply voltage varies
flow rate is too high
inlet temperature is too low
hot water tempera-
ture too low
power supply is too low
All manuals and user guides at all-guides.com
16
Action
open the main water valve / the shut-off valve
fit the special CLAGE jet regulator
check the water flow pressure
remove any dirt from the filter, valves and/or taps
check the technical data
remove any dirt / increase the flow water pressure
close other taps
open the shut-off valve further
check the electric supply
have the fault rectified by a technician and reset the
circuit breaker / safety thermal cut-out
replace heating element (by authorized technician)
check the supply voltage (2/PE 400 V - MH/MDH 7
only)
check installation
adjust the water flow (see fig. 7)
open the shut-off valve, check water pressure
remove dirt from the inlet and outlet pipes
stabilise the water flow pressure
avoid using other taps in the same circuit
(i.e. toilets, washing machines)
check the supply voltage
adjust the flow either at the tap, the valve or the
flow adjustment screw
measure the temperatures and flow rate and compare
with the technical data, check the power supply